tools/xl: add vlan keyword to vif option

Update parse_nic_config() to support a new `vlan' keyword. This
keyword specifies the VLAN configuration to assign to the VIF when
attaching it to the bridge port, on operating systems that support
the capability (e.g. Linux). The vlan keyword will allow one or
more VLANs to be configured on the VIF when adding it to the bridge
port. This will be done by the vif-bridge script and functions.

Signed-off-by: Leigh Brown <leigh@solinno.co.uk>
Reviewed-by: Jason Andryuk <jandryuk@gmail.com>
This commit is contained in:
Leigh Brown authored and Andrew Cooper committed 2024-05-15 19:59:52 +01:00
1 parent 3bc14e4fa4
commit 0cc01c603f
2 files changed
+40

No files matched your search

@@ -259,6 +259,44 @@ Specifies the MTU (i.e. the maximum size of an IP payload, exclusing headers). T
default value is 1500 but, if the VIF is attached to a bridge, it will be set to match
unless overridden by this parameter.
=head2 vlan
Specifies the VLAN configuration. The format of this parameter is one or more
VLAN IDs or ranges separated by forward slashes. Each term can be:
=over
=item *
B<vlan> - a single VLAN ID in the range 1 to 4094. This can optionally followed
by a B<p> to indicate the PVID or by a B<u> to indicate an untagged VLAN. C<p>
implies B<u>.
=item *
B<vlan1>-B<vlan2> - a range of VLAN IDs from B<vlan1> to B<vlan2>, both between
1 and 4094 and B<vlan1> being less than or equal to B<vlan2>. This can be
optionally followed by a B<u> to indicate that the range of VLANs are untagged.
=item *
B<vlan>+B<offset>xB<count> - describing a range of VLAN IDs starting at B<vlan>
with B<count> additional entries, each incremented by B<offset>. This can be
optionally followed by a B<u> to indicate that the range of VLANs are untagged.
=back
Note, one VLAN ID must be marked as the PVID. In the case of a vlan
specification consisting of a single VLAN ID (e.g. C<vlan=10>), the B<p> suffix
may be omitted. Specifying more than one untagged VLAN ID is an advanced
configuration - use with caution.
For example:
'vlan=10' -- meaning a single VLAN that is the PVID.
'vlan=10p/20' -- VLAN 10 is the PVID and VLAN 20 is tagged.
'vlan=10p/100+10x4' -- VLANs 10, 100, 110, 120, 130, 140, 150.
=head2 trusted / untrusted
An advisory setting for the frontend driver on whether the backend should be
+2
View File
@@ -565,6 +565,8 @@ int parse_nic_config(libxl_device_nic *nic, XLU_Config **config, char *token)
nic->devid = parse_ulong(oparg);
} else if (MATCH_OPTION("mtu", token, oparg)) {
nic->mtu = parse_ulong(oparg);
} else if (MATCH_OPTION("vlan", token, oparg)) {
replace_string(&nic->vlan, oparg);
} else if (!strcmp("trusted", token)) {
libxl_defbool_set(&nic->trusted, true);
} else if (!strcmp("untrusted", token)) {