docs: add some missing options to misc/xen-command-line.markdown

These were mostly ones from xen/arch/x86/boot/cmdline.S which are handled early
and therefore do not use the usual infrastructure and so got missed in the
initial trawl.

The document now contains (AFAICT) every still valid option which was
previously documented at:
http://wiki.xen.org/wiki?title=Xen_Hypervisor_Boot_Options&oldid=1379

Signed-off-by: Ian Campbell <ian.campbell@citrix.com>
Committed-by: Ian Jackson <ian.jackson.citrix.com>
This commit is contained in:
Ian Campbell committed 2012-03-26 17:09:59 +01:00
1 parent a77ff6b05c
commit d8fd4c3678
1 file changed
+45
+45
View File
@@ -96,6 +96,10 @@ from the MP tables.
Finally, any of the boolean false options can be used to disable ACPI
usage entirely.
Because responsiblity for ACPI processing is shared between Xen and
the domain 0 kernel this option is automatically propagated to the
domain 0 command line
### acpi\_apic\_instance
> `= <integer>`
@@ -103,7 +107,15 @@ Specify which ACPI MADT table to parse for APIC information, if more
than one is present.
### acpi\_pstate\_strict
### acpi\_skip\_timer\_override
Instruct Xen to ignore timer-interrupt override.
Because responsiblity for ACPI processing is shared between Xen and
the domain 0 kernel this option is automatically propagated to the
domain 0 command line
### acpi\_sleep
### additional\_cpus
### allowsuperpage
@@ -300,8 +312,26 @@ Pin dom0 vcpus to their respective pcpus
### dom\_rid\_bits
### e820-mtrr-clip
### e820-verbose
### edd (x86)
> `= off | on | skipmbr`
Control retrieval of Extended Disc Data (EDD) from the BIOS during
boot.
### edid (x86)
> `= no | force`
Either force retrieval of monitor EDID information via VESA DDC, or
disable it (edid=no). This option should not normally be required
except for debugging purposes.
### efi\_print
### extra\_guest\_irqs
> `= <number>`
Increase the number of PIRQs available for the guest. The default is 32.
### flask\_enabled
### flask\_enforcing
### font
@@ -381,6 +411,15 @@ Specify what Xen should do in the event of an NMI parity or I/O error.
dom0, while 'fatal' causes Xen to print diagnostics and then hang.
### noapic
Instruct Xen to ignore any IOAPICs that are present in the system, and
instead continue to use the legacy PIC. This is _not_ recommended with
pvops type kernels.
Because responsiblity for APIC setup is shared between Xen and the
domain 0 kernel this option is automatically propagated to the domain
0 command line.
### nofxsr
### noirqbalance
> `= <boolean>`
@@ -394,6 +433,12 @@ IRQ routing issues.
Ignore the local APIC on a uniprocessor system, even if enabled by the
BIOS. This option will accept value.
### no-real-mode (x86)
Do not execute real-mode bootstrap code when booting Xen. This option
should not be used except for debugging. It will effectively disable
the vga option, which relies on real mode to set the video mode.
### noreboot
> `= <boolean>`
Reference in new issue