It has been unused since 21732:eb34666befcc.
Removing the include of sys/ptrace.h and threaddb.h exposed a few
places which were using time(2) or gettimeofday(2) without including
time.h or sys/time.h respectively and were relying on an include.
Signed-off-by: Ian Campbell <ian.campbell@citrix.com>
Signed-off-by: Ian Jackson <ian.jackson@eu.citrix.com>
fffedd3d70e1 introduced into tools/python/xen/util/vscsi_util.py
high-bit-set characters which appear to be UTF-8 for non-breaking
spaces. Replace them with spaces to avoid getting a Python syntax
error.
Signed-off-by: Ian Jackson <ian.jackson@eu.citrix.com>
We have pscsi device with long scsi ids like 15:0:11:101.
In this case lsscsi prints no "blank" between id and type,
so the following split of the string returns wrong output.
The field physical_HCTL is set to 15:0:11:101]dis.
The patch replaces char "]" by "] ", so split() will return the right
physical_HTCL.
Signed-off-by: Lutz Dube Lutz.Dube@ts.fujitsu.com
Acked-by: Ian Jackson <ian.jackson@eu.citrix.com>
21866:e017930af272 causes SyntaxError on Python 2.4 or earlier, since
the syntax "true_value if condition else false_value" was introduced
by Python 2.5.
Signed-off-by: KUWAMURA Shin'ya <kuwa@jp.fujitsu.com>
Committed-by: Ian Jackson <ian.jackson@eu.citrix.com>
Xend-API defines the method VM_set_actions_after_crash with valid
action names coredump_and_destroy, coredump_and_restart,... . These
values have to be converted into internal representation
"coredump-destroy", "coredump-restart", ... otherwise start of the
domain is rejected. Same error occurs, if I try to create a VM using
the Xend-API with actions_after_crash set to coredump_and_destroy.
Could you please apply my patch to xen-4-0-testing, too.
Signed-off-by: Lutz Dube Lutz.Dube@ts.fujitsu.com
Acked-by: Jim Fehlig <jfehlig@novell.com>
Committed-by: Ian Jackson <ian.jackson@eu.citrix.com>
On server startup xend start or a later xend restart needs approx. 30 min to
start/restart. Without attached FC devices xend start/restart needs only some
seconds.
server type: Fujitsu Primergy RX600-S5
The time gets lost in xen/xend/XendNode.py line 329 while calling
vscsi_util.get_all_scsi_device().
329 for pscsi_record in vscsi_util.get_all_scsi_devices():
330 scsi_id = pscsi_record['scsi_id']
331 if scsi_id:
332 saved_HBA_uuid = None
I think, in most cases we don't need all the PSCSI devices registered in
xend, but only a few of it.
So a good solution for this perforamce issue is to scan only the SCSI device
paths we need, controlled by a new option in xend-config.sxp.
I have made a patch to allow specification of scsi devices we need in xend
in the config file xend-config.sxp.
The new options pscsi-device-mask expects a list of device ids oder partial
device ids like the option of lsscsi, e.g.
(pscsi-device-mask ('<partial-dev-id1' 'partial-dev-id2' ...))
Without this option set in xend-config.sxp or if lsscsi is not support, all
device paths are process like today.
Signed-off-by: Lutz Dube Lutz.Dube@ts.fujitsu.com
Comment from Masaki Kanno <kanno.masaki@jp.fujitsu.com>: "Well done"
Committed-by: Ian Jackson <ian.jackson@eu.citrix.com>
When create DomU, if bootloader is specified, 'kernel/ramdisk' will be
used by bootloader when boots DomU. So it is needless to check the
path is existent or not.
Signed-off-by: Yu Zhiguo <yuzg@cn.fujitsu.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
add a command "domstate" to get the state of Vms, which may have one state of
{'shutoff', 'idle','shutdown','running','crashed','paused' or 'paused by
admin"}.
For case of pause, I distinguish it into two conditions. One is "paused" the
other is "paused by admin".
"pasued by admin" means that users pause a domain voluntary by "xm paused
VM" or " API"
Signed-off-by James (Song Wei) <jsong@novell.com>
This patch makes the sxp parser show empty string.
Test case:
import sxp
sxp.show(sxp.from_string('(a "")'))
sxp.show(sxp.from_string("(a '')"))
Without this patch:
(a )(a )
With this patch:
(a '')(a '')
Signed-off-by: Zhigang Wang <zhigang.x.wang@oracle.com>
In changeset 21653,
dev_type = sxp.name(dev_config)
should not have been moved, otherwise, the checking "mac"
paragraph is of no use.
(The original patch as submitted was correct but I had to make the
change manually as it had been mangled.)
Signed-off-by: Ian Jackson <ian.jackson@eu.citrix.com>
Signed-off-by Chunyan Liu <CYLiu@novell.com>
The flask library is small, and putting everything in libxenctrl make
relying on flask functionalities in libxl easier.
libflask is left for compatibility purpose, but should be considered
deprecated, and remove in the near future. all flask_ symbols are now
xc_flask_ symbols in libxenctrl.
Signed-off-by: Vincent Hanquez <vincent.hanquez@eu.citrix.com>
In XendDomainInfo.py device_create function, when device type is
"vif", it has a paragraph to check the validity of "mac"
address. Before checking validity, device_add has been done. But after
checking validity, if the mac address is invlid, it raises VmError and
exits directly without doing clean work like removing the device item
from config info. This will cause that the incorrect mac address is
saved into VM Config file and VM fails to restart. If check "mac"
validity before doing device_add, there will be no problem.
Signed-off-by Chunyan Liu <CYLiu@novell.com>
If a command hold domains_lock, "xm list" would hang for waiting for
the lock. Such as creating many VMs at a script (such as 20), command
of "xm list" could hang for long time(10 mins). I think domains_lock
here only protect update(). So, we shouldn't do update before command
of "list" really get this lock, but xm do need show the domain's
information quickly. In this patch, if command couldn't get the
domains_lock after 20 times trying, "xm list" would show the
information of VMs without update().
Signed-off-by: James Song (Wei) <jsong@novell.com>
Writing a NUL terminator here isn't even necessary, since snprintf()
already guarantees proper termination.
Signed-off-by: Jan Beulich <jbeulich@novell.com>
1. Bug fix for error: "Error: Device /dev/xvdp (51952, tap2) is
already connected." (xenstore does not clean after DomU stoped)
2. Bug fix for error: "File 'vhd:/path/.../disk.img' doesn't exist."
(not correct parsing)
3. Bug fix for error: "Error: Device 51952 not connected" (in config
file for DomU we should be use prefix "tap2:tapdisk:xxx" for devices
from (aio, ram, qcow, vhd, remus) or "tap:tapdisk:xxx" for devices
from (sync, vmdk, qcow2, ioemu))
4. Bug fix for error: "Disk is not accessible" (if use 'tap2'-device
type, then '/dev/xpvd' may not be accessible immediately after its
creation)
Signed-off-by: eXeC001er <execooler@gmail.com>
This patch eliminate the global variables in libxenctrl (used for
logging and error reporting).
Instead the information which was in the global variables is now in a
new xc_interface* opaque structure, which xc_interface open returns
instead of the raw file descriptor; furthermore, logging is done via
xentoollog.
There are three new parameters to xc_interface_open to control the
logging, but existing callers can just pass "0" for all three to get
the old behaviour.
All libxc callers have been adjusted accordingly.
Also update QEMU_TAG for corresponding qemu change.
Signed-off-by: Ian Jackson <ian.jackson@eu.citrix.com>
localtime can be stored in vm config as a string, resulting in
incorrect calculation of rtc_timeoffset. Cast localtime to int
to ensure rtc_timeoffset is calculated properly.
Signed-off-by: Jim Fehlig <jfehlig@novell.com>
Add a new feature for xend-relocation-address option to support
definition by interface name which can be useful for people having
e.g. a cluster environment with multiple network interfaces on all of
the machines with only one reserved to be registered to a private
cluster network. This way they won't need to specify the relocation
address manually on all the machines but just simple providing the
interface name to get the IP address from would do the job (all the
machines have to have this interface named the same to make it
working, of course).
Technically it reads the interface name and gets its IP address using
ioctl call of SIOCGIFADDR and if the interface doesn't have the
address, i.e. if non-existing interface or hostname was provided the
original ifname is returned to preserve the old behaviour.
Signed-off-by: Michal Novotny <minovotn@redhat.com>
If you enable legacy tcp xmlrpc in xend's config but omit to enable
ssl then a backtrace is generated when starting xend.
Signed-off-by: Arnd Hannemann <hannemann@nets.rwth-aachen.de>
This allows multiple guests to be migrated or protected by Remus
simultaneously.
Signed-off-by: Shriram Rajagopalan <rshriram@cs.ubc.ca>
Acked-by: Brendan Cully <brendan@cs.ubc.ca>
Fix deprecation warning in Qdisc class under python 2.6.
Fix rtattr length and padding (rta_len is unaligned).
Null-terminate qdisc name in rtnl messages.
Signed-off-by: Brendan Cully <brendan@cs.ubc.ca>
xenstore to release the resource allocated in backend driver
lies in dom0'kernel
Blktapctl thread will use qemu-dm connection instead of tapdisk-ioemu
in the case of FV VM. We found the resource like memory allocated for
this Guest can't be free for backend driver couldn't be closed in qemu-dm.
This patch would remove the backend of tapdisk device earlier in
xenstore to triger qemu-dm to notify the backend driver to release the
resource allocated.
I have tested this patch at the case of
1, save && restore
2, destory && shutdown
3, snapshot
Signed-off-by: James ( Song Wei ) <jsong@novell.com>
If domain creation in xend fails before devices are configured, e.g.
insufficient memory, device config is dropped from xend's managed
domain config.
Once xend is restarted, the domain's devices are lost.
This patch fixes a bug in XendConfig where only the device
controller was consulted for device configuration.
Signed-off-by: Jim Fehlig <jfehlig@novell.com>
blktapctrl supports both 'tapdisk' and 'ioemu' subtypes in tap
protocol specification. Support the 'ioemu' subtype in xend
BlktapController as well.
Signed-off-by: Jim Fehlig <jfehlig@novell.com>
Since we moved several NUMA info fields from physinfo into separate
functions/structures, we must adapt the node picking algorithm, too.
Currently xm create complains about undefined hash values.
The patch uses the new Python xc binding to get the information and
create a reverse mapping for node_to_cpu, since we now only have a
cpu_to_node field.
Signed-off-by: Andre Przywara <andre.przywara@amd.com>