Doug Goldstein 8c271b7584 build: import Kbuild/Kconfig from Linux 4.3
Import the following files and directories from the Linux v4.3 tag /
commit id 6a13feb9c82803e2b815eca72fa7a9f5561d7861.

- scripts/kconfig -> xen/tools/kconfig
- Documentation/kbuild/kconfig{,-language}.txt ->
  docs/misc/kconfig{-language}.txt
- scripts/Makefile.host -> xen/tools/kconfig/Makefile.host

These files are currently unused but will be used shortly.

Signed-off-by: Doug Goldstein <cardoe@cardoe.com>
Acked-by: Jan Beulich <jbeulich@suse.com>
2015-12-16 17:25:15 +01:00
Roger Pau Monne 5ca88cb758 libxl: allow the creation of HVM domains without a device model.
Replace the firmware loaded into HVM guests with an OS kernel. Since the HVM
builder now uses the PV xc_dom_* set of functions this kernel will be parsed
and loaded inside the guest like on PV, but the container is a pure HVM
guest.

Also, if device_model_version is set to none or a device model for the
specified domain is not present unconditinally set the nic type to
LIBXL_NIC_TYPE_VIF.

Signed-off-by: Roger Pau Monné <roger.pau@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
Cc: Ian Jackson <ian.jackson@eu.citrix.com>
Cc: Stefano Stabellini <stefano.stabellini@eu.citrix.com>
Cc: Ian Campbell <ian.campbell@citrix.com>
Cc: Wei Liu <wei.liu2@citrix.com>
2015-12-15 13:25:44 +00:00
Feng Wu b59f4b6e78 VT-d Posted-intterrupt (PI) design
Add the design doc for VT-d PI.

Signed-off-by: Feng Wu <feng.wu@intel.com>
Reviewed-by: Kevin Tian <kevin.tian@intel.com>
Reviewed-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2015-12-10 13:11:25 +01:00
Jan Beulich 4a578b316e memory: split and tighten maximum order permitted in memops
Introduce and enforce separate limits for ordinary DomU, DomU with
pass-through device(s), control domain, and hardware domain.

The DomU defaults were determined based on what so far was allowed by
multipage_allocation_permitted().

The x86 hwdom default was chosen based on linux-2.6.18-xen.hg c/s
1102:82782f1361a9 indicating 2Mb is not enough, plus some slack.

The ARM hwdom default was chosen to allow 2Mb (order-9) mappings, plus
a little bit of slack.

This is CVE-2015-8338 / XSA-158.

Reported-by: Julien Grall <julien.grall@citrix.com>
Signed-off-by: Jan Beulich <jbeulich@suse.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-12-08 14:00:33 +01:00
Kai Huang 484c14b725 x86/vmx: enable PML by default
Since PML series were merged (but disabled by default) we have conducted lots of
PML tests (live migration, GUI display) and PML has been working fine, therefore
turn it on by default.

Document of PML command line is adjusted accordingly as well.

Signed-off-by: Kai Huang <kai.huang@linux.intel.com>
Tested-by: Robert Hu <robert.hu@intel.com>
Tested-by: Xudong Hao <xudong.hao@intel.com>
Reviewed-by: Andrew Cooper <andrew.cooper3@citrix.com>
Tested-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Kevin Tian <kevin.tian@intel.com>
2015-12-02 15:20:19 +01:00
Paul Durrant b38d426ad0 x86/viridian: flush remote tlbs by hypercall
The Microsoft Hypervisor Top Level Functional Spec. (section 3.4) defines
two bits in CPUID leaf 0x40000004:EAX for the hypervisor to recommend
whether or not to issue a hypercall for local or remote TLB flush.

Whilst it's doubtful whether using a hypercall for local TLB flush would
be any more efficient than a specific INVLPG VMEXIT, a remote TLB flush
may well be more efficiently done. This is because the alternative
mechanism is to IPI all the vCPUs in question which (in the absence of
APIC virtualisation) will require emulation and scheduling of the vCPUs
only to have them immediately VMEXIT for local TLB flush.

This patch therefore adds a viridian option which, if selected, enables
the hypercall for remote TLB flush and implements it using ASID
invalidation for targetted vCPUs followed by an IPI only to the set of
CPUs that happened to be running a targetted vCPU (which may be the empty
set). The flush may be more severe than requested since the hypercall can
request flush only for a specific address space (CR3) but Xen neither
keeps a mapping of ASID to guest CR3 nor allows invalidation of a specific
ASID, but on a host with contended CPUs performance is still likely to
be better than a more specific flush using IPIs.

The implementation of the patch introduces per-vCPU viridian_init() and
viridian_deinit() functions to allow a scratch cpumask to be allocated.
This avoids needing to put this potentially large data structure on stack
during hypercall processing. It also modifies the hypercall input and
output bit-fields to allow a check for the 'fast' calling convention,
and a white-space fix in the definition of HVMPV_feature_mask (to remove
hard tabs).

Signed-off-by: Paul Durrant <paul.durrant@citrix.com>
Reviewed-by: Jan Beulich <jbeulich@suse.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-11-26 15:48:41 +01:00
Jan Beulich c03480cf5c x86/vPMU: document as unsupported
This is XSA-163.

Signed-off-by: Jan Beulich <jbeulich@suse.com>
2015-11-24 18:32:20 +01:00
Paul Durrant 26b4f4da89 docs: Introduce xenstore paths for guest network address information
It is useful for a toolstack to be able to see the network addresses
in use by a domain for a particular vif in xenstore for display
purposes and, for example, so that a VNC session can be established
to the guest GUI.

This patch documents paths to allow a domain to advertise an interface
name, MAC (unicast and multicast) and IP (version 4 and 6) address
information.

Signed-off-by: Paul Durrant <paul.durrant@citrix.com>
Cc: Ian Campbell <ian.campbell@citrix.com>
Cc: Ian Jackson <ian.jackson@eu.citrix.com>
Cc: Jan Beulich <jbeulich@suse.com>
Cc: Keir Fraser <keir@xen.org>
Cc: Tim Deegan <tim@xen.org>
Acked-by: Ian Jackson <ian.jackson@eu.citrix.com>
2015-11-24 16:19:00 +00:00
Paul Durrant e8f98cb2d4 docs: Introduce xenstore paths for hotplug features
Without some indication from a guest it is not possible for a
toolstack to know whether instantiation of a new vbd or vif should
result in a new PV device of the appropriate type being brought online.
(In other words whether guest PV drivers are present and functioning).

This patch documents two paths which vif and vbd frontend drivers can
use to advertise their ability to respond to new vif or vbd
instantiations.

Signed-off-by: Paul Durrant <paul.durrant@citrix.com>
Cc: Ian Campbell <ian.campbell@citrix.com>
Cc: Ian Jackson <ian.jackson@eu.citrix.com>
Cc: Jan Beulich <jbeulich@suse.com>
Cc: Keir Fraser <keir@xen.org>
Cc: Tim Deegan <tim@xen.org>
Acked-by: Ian Jackson <ian.jackson@eu.citrix.com>
2015-11-24 16:19:00 +00:00
Paul Durrant 71e64e163b docs: Introduce xenstore paths for PV driver information
For domain management purposes it is convenient to be able to see
information about PV drivers in xenstore. The XAPI toolstack in
XenServer has always created a ~/drivers path for this purpose.

This patch documents that path and also adds a specification of how
it should be used.

Signed-off-by: Paul Durrant <paul.durrant@citrix.com>
Cc: Ian Campbell <ian.campbell@citrix.com>
Cc: Ian Jackson <ian.jackson@eu.citrix.com>
Cc: Jan Beulich <jbeulich@suse.com>
Cc: Keir Fraser <keir@xen.org>
Cc: Tim Deegan <tim@xen.org>
Acked-by: Ian Jackson <ian.jackson@eu.citrix.com>
2015-11-24 16:19:00 +00:00
Paul Durrant 85e3b08eb7 docs: Introduce xenstore paths for PV control features
XenServer already makes use of ~/control/feature-suspend being written
to advertise guest capability of responding to 'suspend' when written to
~/control/shutdown and, since they are derived from XenServer drivers,
the Xen Project Windows PV drivers attempt to write this value. The write
currently fails for libxl provisioned VMs because ~/control is read-only
to the guest (only ~/control/shutdown is writable, for ackowledgement
purposes).

This patch documents feature-suspend and also a set of similar control
feature flags, so that that they may be added to libxl provisioned
guests by subsequent patches:

feature-poweroff: PV drivers/agent can shut down the guest
feature-reboot: PV drivers/agent can reboot the guest
feature-s3: PV drivers/agent can trigger guest sleep (HVM only)
feature-s4: PV drivers/agent can trigger guest hibernate (HVM only)

The patch (bacause it adds features relating to S3 and S4 power states)
also clarifies that the initial set of platform properties mentioned are
booleans, and updates the specifier accordingly.

Signed-off-by: Paul Durrant <paul.durrant@citrix.com>
Cc: Ian Campbell <ian.campbell@citrix.com>
Acked-by: Ian Jackson <ian.jackson@eu.citrix.com>
Cc: Jan Beulich <jbeulich@suse.com>
Cc: Keir Fraser <keir@xen.org>
Cc: Tim Deegan <tim@xen.org>
2015-11-24 16:19:00 +00:00
Stefano Stabellini 84f2fd1ba5 run QEMU as non-root
Try to use "xen-qemuuser-domid$domid" first, then
"xen-qemuuser-shared" and root if everything else fails.

The uids need to be manually created by the user or, more likely, by the
xen package maintainer.

Expose a device_model_user setting in libxl_domain_build_info, so that
opinionated callers, such as libvirt, can set any user they like. Do not
fall back to root if device_model_user is set. Users can also set
device_model_user by hand in the xl domain config file.

QEMU is going to setuid and setgid to the user ID and the group ID of
the specified user, soon after initialization, before starting to deal
with any guest IO.

To actually secure QEMU when running in Dom0, we need at least to
deprivilege the privcmd and xenstore interfaces, this is just the first
step in that direction.

Signed-off-by: Stefano Stabellini <stefano.stabellini@eu.citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-11-16 11:09:41 +00:00
Jan Beulich cc967461e7 ns16550: misc minor adjustments
First and foremost: fix documentation: The use of "clock_hz", when
"base_baud" was meant, has taken me several hours (suspecting a more
complicated problem with the PCIe card I've been trying to get
working). At once correct the "gdb" option, which is more like
"console", not like "com<N>".

Next, fix the types of ns_{read,write}_reg(): Especially the former
having had a signed return type so far caused quite interesting effects
when determining to baud rate if "auto" was specified. In that same
code, also avoid dividing by zero when in fact the baud rate was not
previously set up.

Further, accept I/O port based serial PCI cards with a port range wider
than 8 bytes.

Finally, slightly rearrange struct ns16550 to reduce holes.

Signed-off-by: Jan Beulich <jbeulich@suse.com>
Reviewed-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-11-13 15:41:47 +01:00
Jan Beulich acd9bd133c cpufreq: allow ordinary boolean options to be passed on the command line
I was quite surprised to find "cpufreq=off" not doing what one would
expect it to do. Fix this.

Signed-off-by: Jan Beulich <jbeulich@suse.com>
Reviewed-by: Andrew Cooper <andrew.cooper3@citrix.com>
2015-11-06 15:15:32 +01:00
He Chen fc5b248644 tools & docs: add tools and docs support for Intel CDP
This is the xl/xc changes to support Intel Code/Data Prioritization.
CAT xl commands to set/get CBMs are extended to support CDP.
Add new CDP options with CAT commands in xl interface man page.
Add description of CDP in xl-psr.markdown.

Signed-off-by: He Chen <he.chen@linux.intel.com>
Reviewed-by: Chao Peng <chao.p.peng@linux.intel.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
Reviewed-by: Wei Liu <wei.liu2@citrix.com>
2015-10-22 16:15:09 +01:00
He Chen 56b9a5130f x86: support enable CDP by boot parameter and add get CDP status
Add boot parameter `psr=cdp` to enable CDP at boot time.
Intel Code/Data Prioritization (CDP) feature is based on CAT. Note that
cos_max would be half when CDP is on. struct psr_cat_cbm is extended to
support CDP operation. Extend psr_get_cat_l3_info sysctl to get CDP
status.

Signed-off-by: He Chen <he.chen@linux.intel.com>
Reviewed-by: Andrew Cooper <andrew.cooper3@citrix.com>
Reviewed-by: Chao Peng <chao.p.peng@linux.intel.com>
2015-10-14 12:44:40 +02:00
Ian Campbell 7f25baba1c docs: xl.cfg: permissive option is not PV only.
Since XSA-131 qemu-xen has defaulted to non-permissive mode and the
option was extended to cover that case in 015a373351 "tools: libxl:
allow permissive qemu-upstream pci passthrough".

Since I was rewrapping to adjust the text anyway I've split the safety
warning into a separate paragraph to make it more obvious.

Signed-off-by: Ian Campbell <ian.campbell@citrix.com>
Cc: Eric <epretorious@yahoo.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-10-07 12:25:11 +01:00
Ross Lagerwall 33b55dc103 x86/EPT: work around hardware erratum setting A bit
Since commit 191b3f3344 ("p2m/ept: enable PML in p2m-ept for
log-dirty"), the A and D bits of EPT paging entries are set
unconditionally, regardless of whether PML is enabled or not. This
causes a regression in Xen 4.6 on some processors due to Intel Errata
AVR41 -- HVM guests get severe memory corruption when the A bit is set
due to incorrect TLB flushing on mov to cr3. The erratum affects the
Atom C2000 family (Avoton).

To fix, do not set the A bit on this processor family.

Signed-off-by: Ross Lagerwall <ross.lagerwall@citrix.com>

Move feature suppression to feature detection code. Add command line
override.

Signed-off-by: Jan Beulich <jbeulich@suse.com>
Reviewed-by: Andrew Cooper <andrew.cooper3@citrix.com>
Tested-by: Andrew Cooper <andrew.cooper3@citrix.com>
2015-10-02 13:39:12 +02:00
Chao Peng 61598449ae docs/man: resort sections
Section 'IGNORED FOR COMPATIBILITY WITH XM' separates 'CACHE MONITORING
TECHNOLOGY' and 'CACHE ALLOCATION TECHNOLOGY' but they really should be
put together.

Signed-off-by: Chao Peng <chao.p.peng@linux.intel.com>
Reviewed-by: Dario Faggioli <dario.faggioli@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-09-29 10:58:02 +01:00
Chao Peng 7f732ffa2b docs: make xl-psr.markdown more precise
Drop the chapter number as it can be confusing when it gets changed in
the referred document.

Signed-off-by: Chao Peng <chao.p.peng@linux.intel.com>
Reviewed-by: Dario Faggioli <dario.faggioli@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
[ ijc -- dropped hunk changing URL to specific revision, this is not
         needed now that the references do not include a specific
         chapter number ]
2015-09-29 10:57:30 +01:00
Tiejun Chen 488508b49a libxl: introduce gfx_passthru_kind
Although we already have 'gfx_passthru' in b_info, this doesn't suffice
after we want to handle IGD specifically. Now we define a new field of
type, gfx_passthru_kind, to indicate we're trying to pass IGD. Actually
this means we can benefit this to support other specific devices just
by extending gfx_passthru_kind. And then we can cooperate with
gfx_passthru to address IGD cases as follows:

    gfx_passthru = 0    => sets build_info.u.gfx_passthru to false
    gfx_passthru = 1    => sets build_info.u.gfx_passthru to true and
                           build_info.u.gfx_passthru_kind to DEFAULT
    gfx_passthru = "igd"    => sets build_info.u.gfx_passthru to true
                               and build_info.u.gfx_passthru_kind to IGD

Here if gfx_passthru_kind = DEFAULT, we will call
libxl__is_igd_vga_passthru() to check if we're hitting that table to need
to pass that option to qemu. But if gfx_passthru_kind = "igd" we always
force to pass that.

And "-gfx_passthru" is just introduced to work for qemu-xen-traditional
so we should get this away from libxl__build_device_model_args_new() in
the case of qemu upstream.

Signed-off-by: Tiejun Chen <tiejun.chen@intel.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-09-25 15:59:06 +01:00
Vitaly Kuznetsov c57e6ebd8c (lib)xl: soft reset support
Use existing create/restore path to perform 'soft reset' for HVM
domains. Tear everything down, e.g. destroy domain's device model,
remove the domain from xenstore, save toolstack record and start
over.

Signed-off-by: Vitaly Kuznetsov <vkuznets@redhat.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-09-24 11:46:29 +01:00
Andrew Cooper 112e5346b0 docs: Migration feature document
Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-09-21 12:27:42 +01:00
Andrew Cooper d02bed2a39 docs: Template for feature documents
Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-09-21 12:27:42 +01:00
Wei Liu fa6b5490be xl/libxl: disallow saving a guest with vNUMA configured
This is because the migration stream does not preserve node information.

Note this is not a regression for migration v2 vs legacy migration
because neither of them preserves node information.

Signed-off-by: Wei Liu <wei.liu2@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
[ ijc -- some grammar fixes to the doc and fixed a comment ]
2015-09-11 16:22:03 +01:00
Vitaly Kuznetsov 961a86ba98 libxl: support SHUTDOWN_soft_reset shutdown reason
Use letter 'S' to indicate a domain in such state. Introduce new
'on_soft_reset' action and default it to 'restart' for now.

Signed-off-by: Vitaly Kuznetsov <vkuznets@redhat.com>
Reviewed-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-09-10 16:52:08 +02:00
Ian Campbell a1d95d0f87 Rerun autogen.sh to pickup new version number
315a8722b4 bumped the version after 4.6
branched. This picks up that change into the generated files.

Signed-off-by: Ian Campbell <ian.campbell@citrix.com>
2015-09-10 12:30:40 +01:00
Andrew Cooper 6a05af2459 docs: Fix installation of man8 pages
c/s a430436 "docs: Support for generating man(8) pages" accidentally
failed to update to the install and clean rules for man8 pages, meaning
that c/s 7b21214 "docs: Move xentrace.8 to docs/man/xentrace.pod.8"
caused a packaging regression when it came to xentop.8

To avoid similar bugs in the future, move the generation of the build,
install and clean rules into the manpage metarule.

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Ian Jackson <ian.jackson@eu.citrix.com>
2015-08-28 10:49:41 +01:00
Andrew Cooper 7b21214a3a docs: Move xentrace.8 to docs/man/xentrace.pod.8
And transform to POD to match our other manpages.

The content is identical, although the formatting was altered slightly
to conform to more usual manpage layout.

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-08-27 19:14:35 +01:00
Andrew Cooper a4304367c4 docs: Support for generating man(8) pages
The manpage rules are very repetative, because of the section number being
present in the filenames.

Instead of adding another set of 3 rules, switch to using a metarule to
automate the repetative action.  New rules for different manpage sections can
be added simply by extending the $(foreach)

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-08-27 19:14:31 +01:00
Andrew Cooper 014b165f9b docs: Move xentrace_format.1 to docs/man/xentrace_format.pod.1
And transform to POD to match our other manpages.

The content is identical (other than one correction), although the
layout differs slightly with certain indentation.

As a correction, remove the reference to xentrace_cpusplit(1) which was
removed in c/s 9b9ca98b6a, more than 10 years ago!

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-08-27 19:14:27 +01:00
Andrew Cooper 570de9c384 docs: Move xentop.1 to docs/man/xentop.pod.1
And transform to POD to match our other manpages.

The content is identical, although the layout differs slightly with
certain indentation.

In addition, adjust the MAN{1,5}SRC-y `find` runes to be more general.

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-08-27 19:14:20 +01:00
Andrew Cooper c85d3d1d98 docs: Move misc README's into docs/misc/
To live with the other documentation.

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-08-27 19:14:17 +01:00
Ting-Wei Lan 146341187a VT-d: add iommu=igfx option to workaround graphics issues
When using Linux >= 3.19 (commit 47591df) as dom0 on some Intel Ironlake
devices, It is possible to encounter graphics issues that make screen
unreadable or crash the system. It was reported in freedesktop bugzilla:

https://bugs.freedesktop.org/show_bug.cgi?id=90037

As we still cannot find a proper fix for this problem, this patch adds
iommu=igfx option to control whether Intel graphics IOMMU is enabled.
Running Xen with iommu=no-igfx is similar to running Linux with
intel_iommu=igfx_off, which disables IOMMU for Intel GPU. This can be
used by users to manually workaround the problem before a fix is
available for i915 driver.

Signed-off-by: Ting-Wei Lan <lantw44@gmail.com>
Reviewed-by: Andrew Cooper <andrew.cooper3@citrix.com>
Release-acked-by: Wei Liu <wei.liu2@citrix.com>
Acked-by: Kevin Tian <kevin.tian@intel.com>
2015-08-06 10:03:53 +01:00
Andrew Cooper 47801b0451 docs/libxl: Re-specify XENSTORE_DATA as EMULATOR_XENSTORE_DATA
The legacy "toolstack" record as implemented in libxl turns out not to
be 32/64bit safe.  As migration v2 has not shipped yet, take this
opportunity to adjust the specification and fix the incompatibility.

Libxl shall loose all knowledge of the old "toolstack" blob and use this
EMULATOR_XENSTORE_DATA record instead.  Compatibility shall be handled
by the legacy conversion script.

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
2015-08-05 10:46:30 +01:00
Wei Liu 27524b5e15 xl/libxl: disable PV vNUMA
Update xl manual and disable PV vNUMA in libxl.

Signed-off-by: Wei Liu <wei.liu2@citrix.com>
Reviewed-by: Dario Faggioli <dario.faggioli@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-07-31 10:15:17 +01:00
Andrew Cooper 5850b0317d docs: Migration v2 is now no longer draft
Add further instructions to the libxc "Future Extensions" section, and
provide such a section for libxl.

In addition, drop the "In experimental __func__" IPRINTF()s from the
libxc implementations.

Finally, a correction to libxl's "Not Yet Included" section which
should have been amended in c/s 7eaec00 when libxl Remus support was
introduced into the protocol.

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
CC: Ian Campbell <Ian.Campbell@citrix.com>
CC: Ian Jackson <Ian.Jackson@eu.citrix.com>
CC: Wei Liu <wei.liu2@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-07-28 11:11:52 +01:00
Andrew Cooper 2591383a50 tools/libx{l, c}: Remove the toolstack_{save, restore} callbacks
Update the libxc spec to indicate more sternly that TOOLSTACK records
should no longer be used.

Also, trim further toolstack infrastructure which should have gone in
c/s 39bf4e9 "tools/libxl: Drop all knowledge of toolstack callbacks"

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
CC: Ian Campbell <Ian.Campbell@citrix.com>
CC: Ian Jackson <Ian.Jackson@eu.citrix.com>
CC: Wei Liu <wei.liu2@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-07-28 11:11:52 +01:00
Ed White ea21400128 x86/altp2m: add altp2mhvm HVM domain parameter
The altp2mhvm and nestedhvm parameters are mutually
exclusive and cannot be set together.

Signed-off-by: Ed White <edmund.h.white@intel.com>
Reviewed-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
Release-acked-by: Wei Liu <wei.liu2@citrix.com>
2015-07-24 13:38:28 +02:00
Ed White fce42d9ad7 x86/HVM: hardware alternate p2m support detection
As implemented here, only supported on platforms with VMX HAP.

By default this functionality is force-disabled, it can be enabled
by specifying altp2m=1 on the Xen command line.

Signed-off-by: Ed White <edmund.h.white@intel.com>
Reviewed-by: Andrew Cooper <andrew.cooper3@citrix.com>
Release-acked-by: Wei Liu <wei.liu2@citrix.com>
2015-07-24 13:26:02 +02:00
Chris (Christopher) Brand a7da1081d1 xen: arm: Document xenheap_megabytes limitation
In setup_mm(), the value passed as xenheap_megabytes gets
converted to pages and passed to setup_xenheap_mappings(),
which in turn passes it to create_32mb_mappings(), which
contains an ASSERT that the value passed is a multiple of
32MB. So specifying any value that is not an integer multiple
of 32 will cause Xen to hit this assert and fail to boot.

Signed-off-by: Chris Brand <chris.brand@broadcom.com>
Reviewed-by: Julien Grall <julien.grall@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-07-24 11:16:11 +01:00
Tiejun Chen bc945aa392 tools: introduce a new parameter to set a predefined rdm boundary
Previously we always fix that predefined boundary as 2G to handle
conflict between memory and rdm, but now this predefined boundar
can be changes with the parameter "rdm_mem_boundary" in .cfg file.

CC: Ian Jackson <ian.jackson@eu.citrix.com>
CC: Stefano Stabellini <stefano.stabellini@eu.citrix.com>
CC: Ian Campbell <ian.campbell@citrix.com>
CC: Wei Liu <wei.liu2@citrix.com>
Signed-off-by: Tiejun Chen <tiejun.chen@intel.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
Acked-by: Ian Jackson <ian.jackson@eu.citrix.com>
Checked-by: Ian Jackson <ian.jackson@eu.citrix.com>
2015-07-23 13:45:26 +01:00
Tiejun Chen 63bc1398ad tools: introduce some new parameters to set rdm policy
This patch introduces user configurable parameters to specify RDM
resource and according policies,

Global RDM parameter:
    rdm = "strategy=host,policy=strict/relaxed"
Per-device RDM parameter:
    pci = [ 'sbdf, rdm_policy=strict/relaxed' ]

Global RDM parameter, "strategy", allows user to specify reserved regions
explicitly, Currently, using 'host' to include all reserved regions reported
on this platform which is good to handle hotplug scenario. In the future
this parameter may be further extended to allow specifying random regions,
e.g. even those belonging to another platform as a preparation for live
migration with passthrough devices. By default this isn't set so we don't
check all rdms. Instead, we just check rdm specific to a given device if
you're assigning this kind of device. Note this option is not recommended
unless you can make sure any conflict does exist.

'strict/relaxed' policy decides how to handle conflict when reserving RDM
regions in pfn space. If conflict exists, 'strict' means an immediate error
so VM can't keep running, while 'relaxed' allows moving forward with a
warning message thrown out.

Default per-device RDM policy is same as default global RDM policy as being
'relaxed'. And the per-device policy would override the global policy like
others.

CC: Ian Jackson <ian.jackson@eu.citrix.com>
CC: Stefano Stabellini <stefano.stabellini@eu.citrix.com>
CC: Ian Campbell <ian.campbell@citrix.com>
CC: Wei Liu <wei.liu2@citrix.com>
Signed-off-by: Tiejun Chen <tiejun.chen@intel.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
Acked-by: Ian Jackson <ian.jackson@eu.citrix.com>
Checked-by: Ian Jackson <ian.jackson@eu.citrix.com>
2015-07-23 13:45:25 +01:00
Andrew Cooper 7eaec00dd9 docs/libxl: Introduce CHECKPOINT_END to support migration v2 remus streams
In a remus scenario, libxc will write a CHECKPOINT record, then hand
ownership of the fd to libxl.  Libxl then writes any records required
and finishes with a CHECKPOINT_END record, then hands ownership of the
fd back to libxc.

Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Ian Campbell <Ian.Campbell@citrix.com>
CC: Ian Jackson <Ian.Jackson@eu.citrix.com>
CC: Wei Liu <wei.liu2@citrix.com>
2015-07-15 11:22:54 +01:00
Andrew Cooper 65f13e2b4c docs: Libxl migration v2 stream specification
Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Acked-by: Ian Campbell <Ian.Campbell@citrix.com>
CC: Ian Jackson <Ian.Jackson@eu.citrix.com>
CC: Wei Liu <wei.liu2@citrix.com>

---
v3: Spelling fixes
2015-07-15 11:22:53 +01:00
Julien Grall 90a100f86c arm: Allow the user to specify the GIC version
A platform may have a GIC compatible with previous version of the
device.

This is allow to virtualize an unmodified OS on new hardware if the GIC
is compatible with older version.

When a guest is created, the vGIC will emulate same version as the
hardware. Although, the user can specify in the configuration file the
preferred version (currently only GICv2 and GICv3 are supported).

Signed-off-by: Julien Grall <julien.grall@citrix.com>
Cc: Ian Jackson <ian.jackson@eu.citrix.com>
Cc: Wei Liu <wei.liu2@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-07-09 12:17:36 +01:00
Fabio Fantoni 05d428addd libxl: Add AHCI support for upstream qemu
Usage:
hdtype=ide|ahci (default=ide)

If hdtype=ahci adds ich9 disk controller in ahci mode and uses it with
upstream qemu to emulate disks instead of ide.
It doesn't support cdroms which still using ide (cdroms will use
"-device ide-cd" as new qemu parameter)
Ahci requires new qemu parameter but for now other emulated disks cases
remains with old ones (I did it in other patch, not needed by this one)
I did it as libxl parameter disabled by default to avoid possible
problems:
- with save/restore/migration (restoring with ahci a domU that was with
ide instead)
- windows < 8 without pv drivers (a registry key change is needed for
AHCI<->IDE change FWIK to avoid possible blue screen)
- windows XP or older that many not support ahci by default.
Setting AHCI with libxl parameter and default to disabled seems the best
solution.
AHCI increase hvm domUs boot performance. On linux hvm domU I saw up to
only 20% of the previous total boot time, whereas boot time decrease a
lot on W7 domUs for most of boots I have done. Small difference in boot
time compared to ide mode on W8 and newer (probably other xen
improvements or fixes are needed not ahci related)

Signed-off-by: Fabio Fantoni <fabio.fantoni@m2r.biz>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
[ ijc -- adjust name of LIBXL_HAVE #define as discussed on list,
         fixup pod syntax in xl.cfg.pod.5 ]
2015-07-09 12:15:16 +01:00
Chao Peng 5bedb5b7c6 docs: add xl-psr.markdown
Add document to introduce basic concepts and terms in PSR family
technologies and the xl interfaces.

Signed-off-by: Chao Peng <chao.p.peng@linux.intel.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-07-09 10:07:38 +01:00
Chao Peng f52fbcf747 tools: add tools support for Intel CAT
This is the xc/xl changes to support Intel Cache Allocation
Technology(CAT).

'xl psr-hwinfo' is updated to show CAT info and two new commands
for CAT are introduced:
- xl psr-cat-cbm-set [-s socket] <domain> <cbm>
  Set cache capacity bitmasks(CBM) for a domain.
- xl psr-cat-show <domain>
  Show CAT domain information.

Examples:
[root@vmm-psr vmm]# xl psr-hwinfo --cat
Cache Allocation Technology (CAT):
Socket ID       : 0
L3 Cache        : 12288KB
Maximum COS     : 15
CBM length      : 12
Default CBM     : 0xfff

[root@vmm-psr vmm]# xl psr-cat-cbm-set 0 0xff

[root@vmm-psr vmm]# xl psr-cat-show
Socket ID       : 0
L3 Cache        : 12288KB
Default CBM     : 0xfff
   ID                     NAME             CBM
    0                 Domain-0            0xff

Signed-off-by: Chao Peng <chao.p.peng@linux.intel.com>
Reviewed-by: Dario Faggioli <dario.faggioli@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
2015-07-09 10:07:38 +01:00
Chao Peng b128c388e9 tools/libxl: add command to show PSR hardware info
Add dedicated one to show hardware information.

[root@vmm-psr]xl psr-hwinfo
Cache Monitoring Technology (CMT):
Enabled         : 1
Total RMID      : 63
Supported monitor types:
cache-occupancy
total-mem-bandwidth
local-mem-bandwidth

Signed-off-by: Chao Peng <chao.p.peng@linux.intel.com>
Reviewed-by: Dario Faggioli <dario.faggioli@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>