=head1 NAME
|
|
|
|
xl - Xen management tool, based on libxenlight
|
|
|
|
=head1 SYNOPSIS
|
|
|
|
B<xl> I<subcommand> [I<args>]
|
|
|
|
=head1 DESCRIPTION
|
|
|
|
The B<xl> program is the new tool for managing Xen guest
|
|
domains. The program can be used to create, pause, and shutdown
|
|
domains. It can also be used to list current domains, enable or pin
|
|
VCPUs, and attach or detach virtual block devices.
|
|
|
|
The basic structure of every B<xl> command is almost always:
|
|
|
|
=over 2
|
|
|
|
B<xl> I<subcommand> [I<OPTIONS>] I<domain-id>
|
|
|
|
=back
|
|
|
|
Where I<subcommand> is one of the subcommands listed below, I<domain-id>
|
|
is the numeric domain id, or the domain name (which will be internally
|
|
translated to domain id), and I<OPTIONS> are subcommand specific
|
|
options. There are a few exceptions to this rule in the cases where
|
|
the subcommand in question acts on all domains, the entire machine,
|
|
or directly on the Xen hypervisor. Those exceptions will be clear for
|
|
each of those subcommands.
|
|
|
|
=head1 NOTES
|
|
|
|
=over 4
|
|
|
|
=item start the script B</etc/init.d/xencommons> at boot time
|
|
|
|
Most B<xl> operations rely upon B<xenstored> and B<xenconsoled>: make
|
|
sure you start the script B</etc/init.d/xencommons> at boot time to
|
|
initialize all the daemons needed by B<xl>.
|
|
|
|
=item setup a B<xenbr0> bridge in dom0
|
|
|
|
In the most common network configuration, you need to setup a bridge in dom0
|
|
named B<xenbr0> in order to have a working network in the guest domains.
|
|
Please refer to the documentation of your Linux distribution to know how to
|
|
setup the bridge.
|
|
|
|
=item B<autoballoon>
|
|
|
|
If you specify the amount of memory dom0 has, passing B<dom0_mem> to
|
|
Xen, it is highly recommended to disable B<autoballoon>. Edit
|
|
B<@XEN_CONFIG_DIR@/xl.conf> and set it to 0.
|
|
|
|
=item run xl as B<root>
|
|
|
|
Most B<xl> commands require root privileges to run due to the
|
|
communications channels used to talk to the hypervisor. Running as
|
|
non root will return an error.
|
|
|
|
=back
|
|
|
|
=head1 GLOBAL OPTIONS
|
|
|
|
Some global options are always available:
|
|
|
|
=over 4
|
|
|
|
=item B<-v>
|
|
|
|
Verbose.
|
|
|
|
=item B<-N>
|
|
|
|
Dry run: do not actually execute the command.
|
|
|
|
=item B<-f>
|
|
|
|
Force execution: xl will refuse to run some commands if it detects that xend is
|
|
also running, this option will force the execution of those commands, even
|
|
though it is unsafe.
|
|
|
|
=item B<-t>
|
|
|
|
Always use carriage-return-based overwriting for displaying progress
|
|
messages without scrolling the screen. Without -t, this is done only
|
|
if stderr is a tty.
|
|
|
|
=item B<-T>
|
|
|
|
Include timestamps and pid of the xl process in output.
|
|
|
|
=back
|
|
|
|
=head1 DOMAIN SUBCOMMANDS
|
|
|
|
The following subcommands manipulate domains directly. As stated
|
|
previously, most commands take I<domain-id> as the first parameter.
|
|
|
|
=over 4
|
|
|
|
=item B<button-press> I<domain-id> I<button>
|
|
|
|
I<This command is deprecated. Please use C<xl trigger> instead.>
|
|
|
|
Indicate an ACPI button press to the domain, where I<button> can be 'power' or
|
|
'sleep'. This command is only available for HVM domains.
|
|
|
|
=item B<create> [I<configfile>] [I<OPTIONS>]
|
|
|
|
The create subcommand takes a config file as its first argument: see
|
|
L<xl.cfg(5)> for full details of the file format and possible options.
|
|
If I<configfile> is missing B<xl> creates the domain assuming the default
|
|
values for every option.
|
|
|
|
I<configfile> has to be an absolute path to a file.
|
|
|
|
Create will return B<as soon> as the domain is started. This B<does
|
|
not> mean the guest OS in the domain has actually booted, or is
|
|
available for input.
|
|
|
|
If the I<-F> option is specified, create will start the domain and not
|
|
return until its death.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-q>, B<--quiet>
|
|
|
|
No console output.
|
|
|
|
=item B<-f=FILE>, B<--defconfig=FILE>
|
|
|
|
Use the given configuration file.
|
|
|
|
=item B<-p>
|
|
|
|
Leave the domain paused after it is created.
|
|
|
|
=item B<-F>
|
|
|
|
Run in foreground until death of the domain.
|
|
|
|
=item B<-V>, B<--vncviewer>
|
|
|
|
Attach to domain's VNC server, forking a vncviewer process.
|
|
|
|
=item B<-A>, B<--vncviewer-autopass>
|
|
|
|
Pass the VNC password to vncviewer via stdin.
|
|
|
|
=item B<-c>
|
|
|
|
Attach console to the domain as soon as it has started. This is
|
|
useful for determining issues with crashing domains and just as a
|
|
general convenience since you often want to watch the
|
|
domain boot.
|
|
|
|
=item B<key=value>
|
|
|
|
It is possible to pass I<key=value> pairs on the command line to provide
|
|
options as if they were written in the configuration file; these override
|
|
whatever is in the I<configfile>.
|
|
|
|
NB: Many config options require characters such as quotes or brackets
|
|
which are interpreted by the shell (and often discarded) before being
|
|
passed to xl, resulting in xl being unable to parse the value
|
|
correctly. A simple work-around is to put all extra options within a
|
|
single set of quotes, separated by semicolons. (See below for an example.)
|
|
|
|
=back
|
|
|
|
B<EXAMPLES>
|
|
|
|
=over 4
|
|
|
|
=item I<with extra parameters>
|
|
|
|
xl create hvm.cfg 'cpus="0-3"; pci=["01:05.1","01:05.2"]'
|
|
|
|
This creates a domain with the file hvm.cfg, but additionally pins it to
|
|
cpus 0-3, and passes through two PCI devices.
|
|
|
|
=back
|
|
|
|
=item B<config-update> I<domain-id> [I<configfile>] [I<OPTIONS>]
|
|
|
|
Update the saved configuration for a running domain. This has no
|
|
immediate effect but will be applied when the guest is next
|
|
restarted. This command is useful to ensure that runtime modifications
|
|
made to the guest will be preserved when the guest is restarted.
|
|
|
|
Since Xen 4.5 xl has improved capabilities to handle dynamic domain
|
|
configuration changes and will preserve any changes made at runtime
|
|
when necessary. Therefore it should not normally be necessary to use
|
|
this command any more.
|
|
|
|
I<configfile> has to be an absolute path to a file.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-f=FILE>, B<--defconfig=FILE>
|
|
|
|
Use the given configuration file.
|
|
|
|
=item B<key=value>
|
|
|
|
It is possible to pass I<key=value> pairs on the command line to
|
|
provide options as if they were written in the configuration file;
|
|
these override whatever is in the I<configfile>. Please see the note
|
|
under I<create> on handling special characters when passing
|
|
I<key=value> pairs on the command line.
|
|
|
|
=back
|
|
|
|
=item B<console> [I<OPTIONS>] I<domain-id>
|
|
|
|
Attach to the console of a domain specified by I<domain-id>. If you've set up
|
|
your domains to have a traditional login console this will look much like a
|
|
normal text login screen.
|
|
|
|
Use the escape character key combination (default Ctrl+]) to detach from the
|
|
domain console.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<-t [pv|serial]>
|
|
|
|
Connect to a PV console or connect to an emulated serial console.
|
|
PV consoles are the only consoles available for PV domains while HVM
|
|
domains can have both. If this option is not specified it defaults to
|
|
emulated serial for HVM guests and PV console for PV guests.
|
|
|
|
=item I<-n NUM>
|
|
|
|
Connect to console number I<NUM>. Console numbers start from 0.
|
|
|
|
=item I<-e escapechar>
|
|
|
|
Customize the escape sequence used to detach from the domain console to
|
|
I<escapechar>. If not specified, the value "^]" is used.
|
|
|
|
=back
|
|
|
|
=item B<destroy> [I<OPTIONS>] I<domain-id>
|
|
|
|
Immediately terminate the domain specified by I<domain-id>. This doesn't give
|
|
the domain OS any chance to react, and is the equivalent of ripping the power
|
|
cord out on a physical machine. In most cases you will want to use the
|
|
B<shutdown> command instead.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<-f>
|
|
|
|
Allow domain 0 to be destroyed. Because a domain cannot destroy itself, this
|
|
is only possible when using a disaggregated toolstack, and is most useful when
|
|
using a hardware domain separated from domain 0.
|
|
|
|
=back
|
|
|
|
=item B<domid> I<domain-name>
|
|
|
|
Converts a domain name to a domain id.
|
|
|
|
=item B<domname> I<domain-id>
|
|
|
|
Converts a domain id to a domain name.
|
|
|
|
=item B<rename> I<domain-id> I<new-name>
|
|
|
|
Change the domain name of a domain specified by I<domain-id> to I<new-name>.
|
|
|
|
=item B<dump-core> I<domain-id> [I<filename>]
|
|
|
|
Dumps the virtual machine's memory for the specified domain to the
|
|
I<filename> specified, without pausing the domain. The dump file will
|
|
be written to a distribution specific directory for dump files, for example:
|
|
@XEN_DUMP_DIR@/dump.
|
|
|
|
=item B<help> [I<--long>]
|
|
|
|
Displays the short help message (i.e. common commands) by default.
|
|
|
|
If the I<--long> option is specified, it displays the complete set of B<xl>
|
|
subcommands, grouped by function.
|
|
|
|
=item B<list> [I<OPTIONS>] [I<domain-id> ...]
|
|
|
|
Displays information about one or more domains. If no domains are
|
|
specified it displays information about all domains.
|
|
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-l>, B<--long>
|
|
|
|
The output for B<xl list> is not the table view shown below, but
|
|
instead presents the data as a JSON data structure.
|
|
|
|
=item B<-Z>, B<--context>
|
|
|
|
Also displays the security labels.
|
|
|
|
=item B<-v>, B<--verbose>
|
|
|
|
Also displays the domain UUIDs, the shutdown reason and security labels.
|
|
|
|
=item B<-c>, B<--cpupool>
|
|
|
|
Also displays the cpupool the domain belongs to.
|
|
|
|
=item B<-n>, B<--numa>
|
|
|
|
Also displays the domain NUMA node affinity.
|
|
|
|
=back
|
|
|
|
B<EXAMPLE>
|
|
|
|
An example format for the list is as follows:
|
|
|
|
Name ID Mem VCPUs State Time(s)
|
|
Domain-0 0 750 4 r----- 11794.3
|
|
win 1 1019 1 r----- 0.3
|
|
linux 2 2048 2 r----- 5624.2
|
|
|
|
Name is the name of the domain. ID the numeric domain id. Mem is the
|
|
desired amount of memory to allocate to the domain (although it may
|
|
not be the currently allocated amount). VCPUs is the number of
|
|
virtual CPUs allocated to the domain. State is the run state (see
|
|
below). Time is the total run time of the domain as accounted for by
|
|
Xen.
|
|
|
|
B<STATES>
|
|
|
|
The State field lists 6 states for a Xen domain, and which ones the
|
|
current domain is in.
|
|
|
|
=over 4
|
|
|
|
=item B<r - running>
|
|
|
|
The domain is currently running on a CPU.
|
|
|
|
=item B<b - blocked>
|
|
|
|
The domain is blocked, and not running or runnable. This can be because the
|
|
domain is waiting on IO (a traditional wait state) or has
|
|
gone to sleep because there was nothing else for it to do.
|
|
|
|
=item B<p - paused>
|
|
|
|
The domain has been paused, usually occurring through the administrator
|
|
running B<xl pause>. When in a paused state the domain will still
|
|
consume allocated resources (like memory), but will not be eligible for
|
|
scheduling by the Xen hypervisor.
|
|
|
|
=item B<s - shutdown>
|
|
|
|
The guest OS has shut down (SCHEDOP_shutdown has been called) but the
|
|
domain is not dying yet.
|
|
|
|
=item B<c - crashed>
|
|
|
|
The domain has crashed, which is always a violent ending. Usually
|
|
this state only occurs if the domain has been configured not to
|
|
restart on a crash. See L<xl.cfg(5)> for more info.
|
|
|
|
=item B<d - dying>
|
|
|
|
The domain is in the process of dying, but hasn't completely shut down or
|
|
crashed.
|
|
|
|
=back
|
|
|
|
B<NOTES>
|
|
|
|
=over 4
|
|
|
|
The Time column is deceptive. Virtual IO (network and block devices)
|
|
used by the domains requires coordination by Domain0, which means that
|
|
Domain0 is actually charged for much of the time that a DomainU is
|
|
doing IO. Use of this time value to determine relative utilizations
|
|
by domains is thus very unreliable, as a high IO workload may show as
|
|
less utilized than a high CPU workload. Consider yourself warned.
|
|
|
|
=back
|
|
|
|
=item B<mem-set> I<domain-id> I<mem>
|
|
|
|
Set the target for the domain's balloon driver.
|
|
|
|
The default unit is kiB. Add 't' for TiB, 'g' for GiB, 'm' for
|
|
MiB, 'k' for kiB, and 'b' for bytes (e.g., `2048m` for 2048 MiB).
|
|
|
|
This must be less than the initial B<maxmem> parameter in the domain's
|
|
configuration.
|
|
|
|
Note that this operation requests the guest operating system's balloon
|
|
driver to reach the target amount of memory. The guest may fail to
|
|
reach that amount of memory for any number of reasons, including:
|
|
|
|
=over 4
|
|
|
|
=item
|
|
|
|
The guest doesn't have a balloon driver installed
|
|
|
|
=item
|
|
|
|
The guest's balloon driver is buggy
|
|
|
|
=item
|
|
|
|
The guest's balloon driver cannot create free guest memory due to
|
|
guest memory pressure
|
|
|
|
=item
|
|
|
|
The guest's balloon driver cannot allocate memory from Xen because of
|
|
hypervisor memory pressure
|
|
|
|
=item
|
|
|
|
The guest administrator has disabled the balloon driver
|
|
|
|
=back
|
|
|
|
B<Warning:> There is no good way to know in advance how small of a
|
|
mem-set will make a domain unstable and cause it to crash. Be very
|
|
careful when using this command on running domains.
|
|
|
|
=item B<mem-max> I<domain-id> I<mem>
|
|
|
|
Specify the limit Xen will place on the amount of memory a guest may
|
|
allocate.
|
|
|
|
The default unit is kiB. Add 't' for TiB, 'g' for GiB, 'm' for
|
|
MiB, 'k' for kiB, and 'b' for bytes (e.g., `2048m` for 2048 MiB).
|
|
|
|
I<mem> can't be set lower than the current memory target for
|
|
I<domain-id>. It is allowed to be higher than the configured maximum
|
|
memory size of the domain (B<maxmem> parameter in the domain's
|
|
configuration).
|
|
|
|
Setting the maximum memory size above the configured maximum memory size
|
|
will require special guest support (memory hotplug) in order to be usable
|
|
by the guest.
|
|
|
|
The domain will not receive any signal regarding the changed memory
|
|
limit.
|
|
|
|
=item B<migrate> [I<OPTIONS>] I<domain-id> I<host>
|
|
|
|
Migrate a domain to another host machine. By default B<xl> relies on ssh as a
|
|
transport mechanism between the two hosts.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-s> I<sshcommand>
|
|
|
|
Use <sshcommand> instead of ssh. String will be passed to sh. If empty, run
|
|
<host> instead of ssh <host> xl migrate-receive [-d -e].
|
|
|
|
=item B<-e>
|
|
|
|
On the new <host>, do not wait in the background for the death of the
|
|
domain. See the corresponding option of the I<create> subcommand.
|
|
|
|
=item B<-C> I<config>
|
|
|
|
Send the specified <config> file instead of the file used on creation of the
|
|
domain.
|
|
|
|
=item B<--debug>
|
|
|
|
Display huge (!) amount of debug information during the migration process.
|
|
|
|
=item B<-p>
|
|
|
|
Leave the domain on the receive side paused after migration.
|
|
|
|
=item B<-D>
|
|
|
|
Preserve the B<domain-id> in the domain coniguration that is transferred
|
|
such that it will be identical on the destination host, unless that
|
|
configuration is overridden using the B<-C> option. Note that it is not
|
|
possible to use this option for a 'localhost' migration.
|
|
|
|
=back
|
|
|
|
=item B<remus> [I<OPTIONS>] I<domain-id> I<host>
|
|
|
|
Enable Remus HA or COLO HA for domain. By default B<xl> relies on ssh as a
|
|
transport mechanism between the two hosts.
|
|
|
|
B<NOTES>
|
|
|
|
=over 4
|
|
|
|
Remus support in xl is still in experimental (proof-of-concept) phase.
|
|
Disk replication support is limited to DRBD disks.
|
|
|
|
COLO support in xl is still in experimental (proof-of-concept)
|
|
phase. All options are subject to change in the future.
|
|
|
|
=back
|
|
|
|
COLO disk configuration looks like:
|
|
|
|
disk = ['...,colo,colo-host=xxx,colo-port=xxx,colo-export=xxx,active-disk=xxx,hidden-disk=xxx...']
|
|
|
|
The supported options are:
|
|
|
|
=over 4
|
|
|
|
=item B<colo-host> : Secondary host's ip address.
|
|
|
|
=item B<colo-port> : Secondary host's port, we will run a nbd server on the
|
|
secondary host, and the nbd server will listen on this port.
|
|
|
|
=item B<colo-export> : Nbd server's disk export name of the secondary host.
|
|
|
|
=item B<active-disk> : Secondary's guest write will be buffered to this disk,
|
|
and it's used by the secondary.
|
|
|
|
=item B<hidden-disk> : Primary's modified contents will be buffered in this
|
|
disk, and it's used by the secondary.
|
|
|
|
=back
|
|
|
|
COLO network configuration looks like:
|
|
|
|
vif = [ '...,forwarddev=xxx,...']
|
|
|
|
The supported options are:
|
|
|
|
=over 4
|
|
|
|
=item B<forwarddev> : Forward devices for the primary and the secondary, they
|
|
are directly connected.
|
|
|
|
|
|
=back
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-i> I<MS>
|
|
|
|
Checkpoint domain memory every MS milliseconds (default 200ms).
|
|
|
|
=item B<-u>
|
|
|
|
Disable memory checkpoint compression.
|
|
|
|
=item B<-s> I<sshcommand>
|
|
|
|
Use <sshcommand> instead of ssh. String will be passed to sh.
|
|
If empty, run <host> instead of ssh <host> xl migrate-receive -r [-e].
|
|
|
|
=item B<-e>
|
|
|
|
On the new <host>, do not wait in the background for the death of the domain.
|
|
See the corresponding option of the I<create> subcommand.
|
|
|
|
=item B<-N> I<netbufscript>
|
|
|
|
Use <netbufscript> to setup network buffering instead of the
|
|
default script (@XEN_SCRIPT_DIR@/remus-netbuf-setup).
|
|
|
|
=item B<-F>
|
|
|
|
Run Remus in unsafe mode. Use this option with caution as failover may
|
|
not work as intended.
|
|
|
|
=item B<-b>
|
|
|
|
Replicate memory checkpoints to /dev/null (blackhole).
|
|
Generally useful for debugging. Requires enabling unsafe mode.
|
|
|
|
=item B<-n>
|
|
|
|
Disable network output buffering. Requires enabling unsafe mode.
|
|
|
|
=item B<-d>
|
|
|
|
Disable disk replication. Requires enabling unsafe mode.
|
|
|
|
=item B<-c>
|
|
|
|
Enable COLO HA. This conflicts with B<-i> and B<-b>, and memory
|
|
checkpoint compression must be disabled.
|
|
|
|
=item B<-p>
|
|
|
|
Use userspace COLO Proxy. This option must be used in conjunction
|
|
with B<-c>.
|
|
|
|
=back
|
|
|
|
=item B<pause> I<domain-id>
|
|
|
|
Pause a domain. When in a paused state the domain will still consume
|
|
allocated resources (such as memory), but will not be eligible for
|
|
scheduling by the Xen hypervisor.
|
|
|
|
=item B<reboot> [I<OPTIONS>] I<domain-id>
|
|
|
|
Reboot a domain. This acts just as if the domain had the B<reboot>
|
|
command run from the console. The command returns as soon as it has
|
|
executed the reboot action, which may be significantly earlier than when the
|
|
domain actually reboots.
|
|
|
|
For HVM domains this requires PV drivers to be installed in your guest
|
|
OS. If PV drivers are not present but you have configured the guest OS
|
|
to behave appropriately you may be able to use the I<-F> option to
|
|
trigger a reset button press.
|
|
|
|
The behavior of what happens to a domain when it reboots is set by the
|
|
B<on_reboot> parameter of the domain configuration file when the
|
|
domain was created.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-F>
|
|
|
|
If the guest does not support PV reboot control then fallback to
|
|
sending an ACPI power event (equivalent to the I<reset> option to
|
|
I<trigger>).
|
|
|
|
You should ensure that the guest is configured to behave as expected
|
|
in response to this event.
|
|
|
|
=back
|
|
|
|
=item B<restore> [I<OPTIONS>] [I<configfile>] I<checkpointfile>
|
|
|
|
Build a domain from an B<xl save> state file. See B<save> for more info.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-p>
|
|
|
|
Do not unpause the domain after restoring it.
|
|
|
|
=item B<-e>
|
|
|
|
Do not wait in the background for the death of the domain on the new host.
|
|
See the corresponding option of the I<create> subcommand.
|
|
|
|
=item B<-d>
|
|
|
|
Enable debug messages.
|
|
|
|
=item B<-V>, B<--vncviewer>
|
|
|
|
Attach to the domain's VNC server, forking a vncviewer process.
|
|
|
|
=item B<-A>, B<--vncviewer-autopass>
|
|
|
|
Pass the VNC password to vncviewer via stdin.
|
|
|
|
|
|
|
|
=back
|
|
|
|
=item B<resume> I<domain-id>
|
|
|
|
Resume a domain, after having been suspended.
|
|
|
|
=item B<save> [I<OPTIONS>] I<domain-id> I<checkpointfile> [I<configfile>]
|
|
|
|
Saves a running domain to a state file so that it can be restored
|
|
later. Once saved, the domain will no longer be running on the
|
|
system, unless the -c or -p options are used.
|
|
B<xl restore> restores from this checkpoint file.
|
|
Passing a config file argument allows the user to manually select the VM config
|
|
file used to create the domain.
|
|
|
|
=over 4
|
|
|
|
=item B<-c>
|
|
|
|
Leave the domain running after creating the snapshot.
|
|
|
|
=item B<-p>
|
|
|
|
Leave the domain paused after creating the snapshot.
|
|
|
|
=item B<-D>
|
|
|
|
Preserve the B<domain-id> in the domain coniguration that is embedded in
|
|
the state file such that it will be identical when the domain is restored,
|
|
unless that configuration is overridden. (See the B<restore> operation
|
|
above).
|
|
|
|
=back
|
|
|
|
=item B<sharing> [I<domain-id>]
|
|
|
|
Display the number of shared pages for a specified domain. If no domain is
|
|
specified it displays information about all domains.
|
|
|
|
=item B<shutdown> [I<OPTIONS>] I<-a|domain-id>
|
|
|
|
Gracefully shuts down a domain. This coordinates with the domain OS
|
|
to perform graceful shutdown, so there is no guarantee that it will
|
|
succeed, and may take a variable length of time depending on what
|
|
services must be shut down in the domain.
|
|
|
|
For HVM domains this requires PV drivers to be installed in your guest
|
|
OS. If PV drivers are not present but you have configured the guest OS
|
|
to behave appropriately you may be able to use the I<-F> option to
|
|
trigger a power button press.
|
|
|
|
The command returns immediately after signaling the domain unless the
|
|
B<-w> flag is used.
|
|
|
|
The behavior of what happens to a domain when it reboots is set by the
|
|
B<on_shutdown> parameter of the domain configuration file when the
|
|
domain was created.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-a>, B<--all>
|
|
|
|
Shutdown all guest domains. Often used when doing a complete shutdown
|
|
of a Xen system.
|
|
|
|
=item B<-w>, B<--wait>
|
|
|
|
Wait for the domain to complete shutdown before returning. If given once,
|
|
the wait is for domain shutdown or domain death. If given multiple times,
|
|
the wait is for domain death only.
|
|
|
|
=item B<-F>
|
|
|
|
If the guest does not support PV shutdown control then fallback to
|
|
sending an ACPI power event (equivalent to the I<power> option to
|
|
I<trigger>).
|
|
|
|
You should ensure that the guest is configured to behave as expected
|
|
in response to this event.
|
|
|
|
=back
|
|
|
|
=item B<suspend> I<domain-id>
|
|
|
|
Suspend a domain. This is a cooperative operation where the domain must
|
|
respond to the xenstore trigger. When in a suspended state the domain
|
|
still consumes allocated resources (such as memory), but is not eligible
|
|
for scheduling by the Xen hypervisor. It is in a shutdown state, but
|
|
not dying.
|
|
|
|
=item B<sysrq> I<domain-id> I<letter>
|
|
|
|
Send a <Magic System Request> to the domain, each type of request is
|
|
represented by a different letter.
|
|
It can be used to send SysRq requests to Linux guests, see sysrq.txt in
|
|
your Linux Kernel sources for more information.
|
|
It requires PV drivers to be installed in your guest OS.
|
|
|
|
=item B<trigger> I<domain-id> I<nmi|reset|init|power|sleep|s3resume> [I<VCPU>]
|
|
|
|
Send a trigger to a domain, where the trigger can be: nmi, reset, init, power
|
|
or sleep. Optionally a specific vcpu number can be passed as an argument.
|
|
This command is only available for HVM domains.
|
|
|
|
=item B<unpause> I<domain-id>
|
|
|
|
Moves a domain out of the paused state. This will allow a previously
|
|
paused domain to now be eligible for scheduling by the Xen hypervisor.
|
|
|
|
=item B<vcpu-set> I<domain-id> I<vcpu-count>
|
|
|
|
Enables the I<vcpu-count> virtual CPUs for the domain in question.
|
|
Like mem-set, this command can only allocate up to the maximum virtual
|
|
CPU count configured at boot for the domain.
|
|
|
|
If the I<vcpu-count> is smaller than the current number of active
|
|
VCPUs, the highest number VCPUs will be hotplug removed. This may be
|
|
important for pinning purposes.
|
|
|
|
Attempting to set the VCPUs to a number larger than the initially
|
|
configured VCPU count is an error. Trying to set VCPUs to < 1 will be
|
|
quietly ignored.
|
|
|
|
Some guests may need to actually bring the newly added CPU online
|
|
after B<vcpu-set>, go to B<SEE ALSO> section for information.
|
|
|
|
=item B<vcpu-list> [I<domain-id>]
|
|
|
|
Lists VCPU information for a specific domain. If no domain is
|
|
specified, VCPU information for all domains will be provided.
|
|
|
|
=item B<vcpu-pin> [I<-f|--force>] I<domain-id> I<vcpu> I<cpus hard> I<cpus soft>
|
|
|
|
Set hard and soft affinity for a I<vcpu> of <domain-id>. Normally VCPUs
|
|
can float between available CPUs whenever Xen deems a different run state
|
|
is appropriate.
|
|
|
|
Hard affinity can be used to restrict this, by ensuring certain VCPUs
|
|
can only run on certain physical CPUs. Soft affinity specifies a I<preferred>
|
|
set of CPUs. Soft affinity needs special support in the scheduler, which is
|
|
only provided in credit1.
|
|
|
|
The keyword B<all> can be used to apply the hard and soft affinity masks to
|
|
all the VCPUs in the domain. The symbol '-' can be used to leave either
|
|
hard or soft affinity alone.
|
|
|
|
For example:
|
|
|
|
xl vcpu-pin 0 3 - 6-9
|
|
|
|
will set soft affinity for vCPU 3 of domain 0 to pCPUs 6,7,8 and 9,
|
|
leaving its hard affinity untouched. On the other hand:
|
|
|
|
xl vcpu-pin 0 3 3,4 6-9
|
|
|
|
will set both hard and soft affinity, the former to pCPUs 3 and 4, the
|
|
latter to pCPUs 6,7,8, and 9.
|
|
|
|
Specifying I<-f> or I<--force> will remove a temporary pinning done by the
|
|
operating system (normally this should be done by the operating system).
|
|
In case a temporary pinning is active for a vcpu the affinity of this vcpu
|
|
can't be changed without this option.
|
|
|
|
=item B<vm-list>
|
|
|
|
Prints information about guests. This list excludes information about
|
|
service or auxiliary domains such as dom0 and stubdoms.
|
|
|
|
B<EXAMPLE>
|
|
|
|
An example format for the list is as follows:
|
|
|
|
UUID ID name
|
|
59e1cf6c-6ab9-4879-90e7-adc8d1c63bf5 2 win
|
|
50bc8f75-81d0-4d53-b2e6-95cb44e2682e 3 linux
|
|
|
|
=item B<vncviewer> [I<OPTIONS>] I<domain-id>
|
|
|
|
Attach to the domain's VNC server, forking a vncviewer process.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<--autopass>
|
|
|
|
Pass the VNC password to vncviewer via stdin.
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=head1 XEN HOST SUBCOMMANDS
|
|
|
|
=over 4
|
|
|
|
=item B<debug-keys> I<keys>
|
|
|
|
Send debug I<keys> to Xen. It is the same as pressing the Xen
|
|
"conswitch" (Ctrl-A by default) three times and then pressing "keys".
|
|
|
|
=item B<set-parameters> I<params>
|
|
|
|
Set hypervisor parameters as specified in I<params>. This allows for some
|
|
boot parameters of the hypervisor to be modified in the running systems.
|
|
|
|
=item B<dmesg> [I<OPTIONS>]
|
|
|
|
Reads the Xen message buffer, similar to dmesg on a Linux system. The
|
|
buffer contains informational, warning, and error messages created
|
|
during Xen's boot process. If you are having problems with Xen, this
|
|
is one of the first places to look as part of problem determination.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-c>, B<--clear>
|
|
|
|
Clears Xen's message buffer.
|
|
|
|
=back
|
|
|
|
=item B<info> [I<OPTIONS>]
|
|
|
|
Print information about the Xen host in I<name : value> format. When
|
|
reporting a Xen bug, please provide this information as part of the
|
|
bug report. See I<https://wiki.xenproject.org/wiki/Reporting_Bugs_against_Xen_Project> on how to
|
|
report Xen bugs.
|
|
|
|
Sample output looks as follows:
|
|
|
|
host : scarlett
|
|
release : 3.1.0-rc4+
|
|
version : #1001 SMP Wed Oct 19 11:09:54 UTC 2011
|
|
machine : x86_64
|
|
nr_cpus : 4
|
|
nr_nodes : 1
|
|
cores_per_socket : 4
|
|
threads_per_core : 1
|
|
cpu_mhz : 2266
|
|
hw_caps : bfebfbff:28100800:00000000:00003b40:009ce3bd:00000000:00000001:00000000
|
|
virt_caps : hvm hvm_directio
|
|
total_memory : 6141
|
|
free_memory : 4274
|
|
free_cpus : 0
|
|
outstanding_claims : 0
|
|
xen_major : 4
|
|
xen_minor : 2
|
|
xen_extra : -unstable
|
|
xen_caps : xen-3.0-x86_64 xen-3.0-x86_32p hvm-3.0-x86_32 hvm-3.0-x86_32p hvm-3.0-x86_64
|
|
xen_scheduler : credit
|
|
xen_pagesize : 4096
|
|
platform_params : virt_start=0xffff800000000000
|
|
xen_changeset : Wed Nov 02 17:09:09 2011 +0000 24066:54a5e994a241
|
|
xen_commandline : com1=115200,8n1 guest_loglvl=all dom0_mem=750M console=com1
|
|
cc_compiler : gcc version 4.4.5 (Debian 4.4.5-8)
|
|
cc_compile_by : sstabellini
|
|
cc_compile_domain : uk.xensource.com
|
|
cc_compile_date : Tue Nov 8 12:03:05 UTC 2011
|
|
xend_config_format : 4
|
|
|
|
|
|
B<FIELDS>
|
|
|
|
Not all fields will be explained here, but some of the less obvious
|
|
ones deserve explanation:
|
|
|
|
=over 4
|
|
|
|
=item B<hw_caps>
|
|
|
|
A vector showing what hardware capabilities are supported by your
|
|
processor. This is equivalent to, though more cryptic, the flags
|
|
field in /proc/cpuinfo on a normal Linux machine: they both derive from
|
|
the feature bits returned by the cpuid command on x86 platforms.
|
|
|
|
=item B<free_memory>
|
|
|
|
Available memory (in MB) not allocated to Xen, or any other domains, or
|
|
claimed for domains.
|
|
|
|
=item B<outstanding_claims>
|
|
|
|
When a claim call is done (see L<xl.conf(5)>) a reservation for a specific
|
|
amount of pages is set and also a global value is incremented. This
|
|
global value (outstanding_claims) is then reduced as the domain's memory
|
|
is populated and eventually reaches zero. Most of the time the value will
|
|
be zero, but if you are launching multiple guests, and B<claim_mode> is
|
|
enabled, this value can increase/decrease. Note that the value also
|
|
affects the B<free_memory> - as it will reflect the free memory
|
|
in the hypervisor minus the outstanding pages claimed for guests.
|
|
See xl I<info> B<claims> parameter for detailed listing.
|
|
|
|
=item B<xen_caps>
|
|
|
|
The Xen version and architecture. Architecture values can be one of:
|
|
x86_32, x86_32p (i.e. PAE enabled), x86_64, ia64.
|
|
|
|
=item B<xen_changeset>
|
|
|
|
The Xen mercurial changeset id. Very useful for determining exactly
|
|
what version of code your Xen system was built from.
|
|
|
|
=back
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-n>, B<--numa>
|
|
|
|
List host NUMA topology information
|
|
|
|
=item B<-x>, B<--xenstore>
|
|
|
|
Show Xenstore features available.
|
|
|
|
=back
|
|
|
|
=item B<top>
|
|
|
|
Executes the B<xentop(1)> command, which provides real time monitoring of
|
|
domains. Xentop has a curses interface, and is reasonably self explanatory.
|
|
|
|
=item B<uptime>
|
|
|
|
Prints the current uptime of the domains running.
|
|
|
|
=item B<claims>
|
|
|
|
Prints information about outstanding claims by the guests. This provides
|
|
the outstanding claims and currently populated memory count for the guests.
|
|
These values added up reflect the global outstanding claim value, which
|
|
is provided via the I<info> argument, B<outstanding_claims> value.
|
|
The B<Mem> column has the cumulative value of outstanding claims and
|
|
the total amount of memory that has been right now allocated to the guest.
|
|
|
|
B<EXAMPLE>
|
|
|
|
An example format for the list is as follows:
|
|
|
|
Name ID Mem VCPUs State Time(s) Claimed
|
|
Domain-0 0 2047 4 r----- 19.7 0
|
|
OL5 2 2048 1 --p--- 0.0 847
|
|
OL6 3 1024 4 r----- 5.9 0
|
|
Windows_XP 4 2047 1 --p--- 0.0 1989
|
|
|
|
In which it can be seen that the OL5 guest still has 847MB of claimed
|
|
memory (out of the total 2048MB where 1191MB has been allocated to
|
|
the guest).
|
|
|
|
=back
|
|
|
|
=head1 SCHEDULER SUBCOMMANDS
|
|
|
|
Xen ships with a number of domain schedulers, which can be set at boot
|
|
time with the B<sched=> parameter on the Xen command line. By
|
|
default B<credit> is used for scheduling.
|
|
|
|
=over 4
|
|
|
|
=item B<sched-credit> [I<OPTIONS>]
|
|
|
|
Set or get credit (aka credit1) scheduler parameters. The credit scheduler is
|
|
a proportional fair share CPU scheduler built from the ground up to be
|
|
work conserving on SMP hosts.
|
|
|
|
Each domain (including Domain0) is assigned a weight and a cap.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-d DOMAIN>, B<--domain=DOMAIN>
|
|
|
|
Specify domain for which scheduler parameters are to be modified or retrieved.
|
|
Mandatory for modifying scheduler parameters.
|
|
|
|
=item B<-w WEIGHT>, B<--weight=WEIGHT>
|
|
|
|
A domain with a weight of 512 will get twice as much CPU as a domain
|
|
with a weight of 256 on a contended host. Legal weights range from 1
|
|
to 65535 and the default is 256.
|
|
|
|
=item B<-c CAP>, B<--cap=CAP>
|
|
|
|
The cap optionally fixes the maximum amount of CPU a domain will be
|
|
able to consume, even if the host system has idle CPU cycles. The cap
|
|
is expressed in percentage of one physical CPU: 100 is 1 physical CPU,
|
|
50 is half a CPU, 400 is 4 CPUs, etc. The default, 0, means there is
|
|
no upper cap.
|
|
|
|
NB: Many systems have features that will scale down the computing
|
|
power of a cpu that is not 100% utilized. This can be in the
|
|
operating system, but can also sometimes be below the operating system
|
|
in the BIOS. If you set a cap such that individual cores are running
|
|
at less than 100%, this may have an impact on the performance of your
|
|
workload over and above the impact of the cap. For example, if your
|
|
processor runs at 2GHz, and you cap a vm at 50%, the power management
|
|
system may also reduce the clock speed to 1GHz; the effect will be
|
|
that your VM gets 25% of the available power (50% of 1GHz) rather than
|
|
50% (50% of 2GHz). If you are not getting the performance you expect,
|
|
look at performance and cpufreq options in your operating system and
|
|
your BIOS.
|
|
|
|
=item B<-p CPUPOOL>, B<--cpupool=CPUPOOL>
|
|
|
|
Restrict output to domains in the specified cpupool.
|
|
|
|
=item B<-s>, B<--schedparam>
|
|
|
|
Specify to list or set pool-wide scheduler parameters.
|
|
|
|
=item B<-t TSLICE>, B<--tslice_ms=TSLICE>
|
|
|
|
Timeslice tells the scheduler how long to allow VMs to run before
|
|
pre-empting. The default is 30ms. Valid ranges are 1ms to 1000ms.
|
|
The length of the timeslice (in ms) must be higher than the length of
|
|
the ratelimit (see below).
|
|
|
|
=item B<-r RLIMIT>, B<--ratelimit_us=RLIMIT>
|
|
|
|
Ratelimit attempts to limit the number of schedules per second. It
|
|
sets a minimum amount of time (in microseconds) a VM must run before
|
|
we will allow a higher-priority VM to pre-empt it. The default value
|
|
is 1000 microseconds (1ms). Valid range is 100 to 500000 (500ms).
|
|
The ratelimit length must be lower than the timeslice length.
|
|
|
|
=item B<-m DELAY>, B<--migration_delay_us=DELAY>
|
|
|
|
Migration delay specifies for how long a vCPU, after it stopped running should
|
|
be considered "cache-hot". Basically, if less than DELAY us passed since when
|
|
the vCPU was executing on a CPU, it is likely that most of the vCPU's working
|
|
set is still in the CPU's cache, and therefore the vCPU is not migrated.
|
|
|
|
Default is 0. Maximum is 100 ms. This can be effective at preventing vCPUs
|
|
to bounce among CPUs too quickly, but, at the same time, the scheduler stops
|
|
being fully work-conserving.
|
|
|
|
=back
|
|
|
|
B<COMBINATION>
|
|
|
|
The following is the effect of combining the above options:
|
|
|
|
=over 4
|
|
|
|
=item B<E<lt>nothingE<gt>> : List all domain params and sched params from all pools
|
|
|
|
=item B<-d [domid]> : List domain params for domain [domid]
|
|
|
|
=item B<-d [domid] [params]> : Set domain params for domain [domid]
|
|
|
|
=item B<-p [pool]> : list all domains and sched params for [pool]
|
|
|
|
=item B<-s> : List sched params for poolid 0
|
|
|
|
=item B<-s [params]> : Set sched params for poolid 0
|
|
|
|
=item B<-p [pool] -s> : List sched params for [pool]
|
|
|
|
=item B<-p [pool] -s [params]> : Set sched params for [pool]
|
|
|
|
=item B<-p [pool] -d>... : Illegal
|
|
|
|
=back
|
|
|
|
=item B<sched-credit2> [I<OPTIONS>]
|
|
|
|
Set or get credit2 scheduler parameters. The credit2 scheduler is a
|
|
proportional fair share CPU scheduler built from the ground up to be
|
|
work conserving on SMP hosts.
|
|
|
|
Each domain (including Domain0) is assigned a weight.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-d DOMAIN>, B<--domain=DOMAIN>
|
|
|
|
Specify domain for which scheduler parameters are to be modified or retrieved.
|
|
Mandatory for modifying scheduler parameters.
|
|
|
|
=item B<-w WEIGHT>, B<--weight=WEIGHT>
|
|
|
|
A domain with a weight of 512 will get twice as much CPU as a domain
|
|
with a weight of 256 on a contended host. Legal weights range from 1
|
|
to 65535 and the default is 256.
|
|
|
|
=item B<-p CPUPOOL>, B<--cpupool=CPUPOOL>
|
|
|
|
Restrict output to domains in the specified cpupool.
|
|
|
|
=item B<-s>, B<--schedparam>
|
|
|
|
Specify to list or set pool-wide scheduler parameters.
|
|
|
|
=item B<-r RLIMIT>, B<--ratelimit_us=RLIMIT>
|
|
|
|
Attempts to limit the rate of context switching. It is basically the same
|
|
as B<--ratelimit_us> in B<sched-credit>
|
|
|
|
=back
|
|
|
|
=item B<sched-rtds> [I<OPTIONS>]
|
|
|
|
Set or get rtds (Real Time Deferrable Server) scheduler parameters.
|
|
This rt scheduler applies Preemptive Global Earliest Deadline First
|
|
real-time scheduling algorithm to schedule VCPUs in the system.
|
|
Each VCPU has a dedicated period, budget and extratime.
|
|
While scheduled, a VCPU burns its budget.
|
|
A VCPU has its budget replenished at the beginning of each period;
|
|
Unused budget is discarded at the end of each period.
|
|
A VCPU with extratime set gets extra time from the unreserved system resource.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-d DOMAIN>, B<--domain=DOMAIN>
|
|
|
|
Specify domain for which scheduler parameters are to be modified or retrieved.
|
|
Mandatory for modifying scheduler parameters.
|
|
|
|
=item B<-v VCPUID/all>, B<--vcpuid=VCPUID/all>
|
|
|
|
Specify vcpu for which scheduler parameters are to be modified or retrieved.
|
|
|
|
=item B<-p PERIOD>, B<--period=PERIOD>
|
|
|
|
Period of time, in microseconds, over which to replenish the budget.
|
|
|
|
=item B<-b BUDGET>, B<--budget=BUDGET>
|
|
|
|
Amount of time, in microseconds, that the VCPU will be allowed
|
|
to run every period.
|
|
|
|
=item B<-e Extratime>, B<--extratime=Extratime>
|
|
|
|
Binary flag to decide if the VCPU will be allowed to get extra time from
|
|
the unreserved system resource.
|
|
|
|
=item B<-c CPUPOOL>, B<--cpupool=CPUPOOL>
|
|
|
|
Restrict output to domains in the specified cpupool.
|
|
|
|
=back
|
|
|
|
B<EXAMPLE>
|
|
|
|
=over 4
|
|
|
|
1) Use B<-v all> to see the budget and period of all the VCPUs of
|
|
all the domains:
|
|
|
|
xl sched-rtds -v all
|
|
Cpupool Pool-0: sched=RTDS
|
|
Name ID VCPU Period Budget Extratime
|
|
Domain-0 0 0 10000 4000 yes
|
|
vm1 2 0 300 150 yes
|
|
vm1 2 1 400 200 yes
|
|
vm1 2 2 10000 4000 yes
|
|
vm1 2 3 1000 500 yes
|
|
vm2 4 0 10000 4000 yes
|
|
vm2 4 1 10000 4000 yes
|
|
|
|
Without any arguments, it will output the default scheduling
|
|
parameters for each domain:
|
|
|
|
xl sched-rtds
|
|
Cpupool Pool-0: sched=RTDS
|
|
Name ID Period Budget Extratime
|
|
Domain-0 0 10000 4000 yes
|
|
vm1 2 10000 4000 yes
|
|
vm2 4 10000 4000 yes
|
|
|
|
|
|
2) Use, for instance, B<-d vm1, -v all> to see the budget and
|
|
period of all VCPUs of a specific domain (B<vm1>):
|
|
|
|
xl sched-rtds -d vm1 -v all
|
|
Name ID VCPU Period Budget Extratime
|
|
vm1 2 0 300 150 yes
|
|
vm1 2 1 400 200 yes
|
|
vm1 2 2 10000 4000 yes
|
|
vm1 2 3 1000 500 yes
|
|
|
|
To see the parameters of a subset of the VCPUs of a domain, use:
|
|
|
|
xl sched-rtds -d vm1 -v 0 -v 3
|
|
Name ID VCPU Period Budget Extratime
|
|
vm1 2 0 300 150 yes
|
|
vm1 2 3 1000 500 yes
|
|
|
|
If no B<-v> is specified, the default scheduling parameters for the
|
|
domain are shown:
|
|
|
|
xl sched-rtds -d vm1
|
|
Name ID Period Budget Extratime
|
|
vm1 2 10000 4000 yes
|
|
|
|
|
|
3) Users can set the budget and period of multiple VCPUs of a
|
|
specific domain with only one command,
|
|
e.g., "xl sched-rtds -d vm1 -v 0 -p 100 -b 50 -e 1 -v 3 -p 300 -b 150 -e 0".
|
|
|
|
To change the parameters of all the VCPUs of a domain, use B<-v all>,
|
|
e.g., "xl sched-rtds -d vm1 -v all -p 500 -b 250 -e 1".
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=head1 CPUPOOLS COMMANDS
|
|
|
|
Xen can group the physical cpus of a server in cpu-pools. Each physical CPU is
|
|
assigned at most to one cpu-pool. Domains are each restricted to a single
|
|
cpu-pool. Scheduling does not cross cpu-pool boundaries, so each cpu-pool has
|
|
its own scheduler.
|
|
Physical cpus and domains can be moved from one cpu-pool to another only by an
|
|
explicit command.
|
|
Cpu-pools can be specified either by name or by id.
|
|
|
|
=over 4
|
|
|
|
=item B<cpupool-create> [I<OPTIONS>] [I<configfile>] [I<variable=value> ...]
|
|
|
|
Create a cpu pool based an config from a I<configfile> or command-line
|
|
parameters. Variable settings from the I<configfile> may be altered
|
|
by specifying new or additional assignments on the command line.
|
|
|
|
See the L<xlcpupool.cfg(5)> manpage for more information.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-f=FILE>, B<--defconfig=FILE>
|
|
|
|
Use the given configuration file.
|
|
|
|
=back
|
|
|
|
=item B<cpupool-list> [I<OPTIONS>] [I<cpu-pool>]
|
|
|
|
List CPU pools on the host.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-c>, B<--cpus>
|
|
|
|
If this option is specified, B<xl> prints a list of CPUs used by I<cpu-pool>.
|
|
|
|
=back
|
|
|
|
=item B<cpupool-destroy> I<cpu-pool>
|
|
|
|
Deactivates a cpu pool.
|
|
This is possible only if no domain is active in the cpu-pool.
|
|
|
|
=item B<cpupool-rename> I<cpu-pool> <newname>
|
|
|
|
Renames a cpu-pool to I<newname>.
|
|
|
|
=item B<cpupool-cpu-add> I<cpu-pool> I<cpus|node:nodes>
|
|
|
|
Adds one or more CPUs or NUMA nodes to I<cpu-pool>. CPUs and NUMA
|
|
nodes can be specified as single CPU/node IDs or as ranges.
|
|
|
|
For example:
|
|
|
|
(a) xl cpupool-cpu-add mypool 4
|
|
(b) xl cpupool-cpu-add mypool 1,5,10-16,^13
|
|
(c) xl cpupool-cpu-add mypool node:0,nodes:2-3,^10-12,8
|
|
|
|
means adding CPU 4 to mypool, in (a); adding CPUs 1,5,10,11,12,14,15
|
|
and 16, in (b); and adding all the CPUs of NUMA nodes 0, 2 and 3,
|
|
plus CPU 8, but keeping out CPUs 10,11,12, in (c).
|
|
|
|
All the specified CPUs that can be added to the cpupool will be added
|
|
to it. If some CPU can't (e.g., because they're already part of another
|
|
cpupool), an error is reported about each one of them.
|
|
|
|
=item B<cpupool-cpu-remove> I<cpu-pool> I<cpus|node:nodes>
|
|
|
|
Removes one or more CPUs or NUMA nodes from I<cpu-pool>. CPUs and NUMA
|
|
nodes can be specified as single CPU/node IDs or as ranges, using the
|
|
exact same syntax as in B<cpupool-cpu-add> above.
|
|
|
|
=item B<cpupool-migrate> I<domain-id> I<cpu-pool>
|
|
|
|
Moves a domain specified by domain-id or domain-name into a cpu-pool.
|
|
Domain-0 can't be moved to another cpu-pool.
|
|
|
|
=item B<cpupool-numa-split>
|
|
|
|
Splits up the machine into one cpu-pool per numa node.
|
|
|
|
=back
|
|
|
|
=head1 VIRTUAL DEVICE COMMANDS
|
|
|
|
Most virtual devices can be added and removed while guests are
|
|
running, assuming that the necessary support exists in the guest OS. The
|
|
effect to the guest OS is much the same as any hotplug event.
|
|
|
|
=head2 BLOCK DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<block-attach> I<domain-id> I<disc-spec-component(s)> ...
|
|
|
|
Create a new virtual block device and attach it to the specified domain.
|
|
A disc specification is in the same format used for the B<disk> variable in
|
|
the domain config file. See L<xl-disk-configuration(5)>. This will trigger a
|
|
hotplug event for the guest.
|
|
|
|
Note that only PV block devices are supported by block-attach.
|
|
Requests to attach emulated devices (eg, vdev=hdc) will result in only
|
|
the PV view being available to the guest.
|
|
|
|
=item B<block-detach> [I<OPTIONS>] I<domain-id> I<devid>
|
|
|
|
Detach a domain's virtual block device. I<devid> may be the symbolic
|
|
name or the numeric device id given to the device by domain 0. You
|
|
will need to run B<xl block-list> to determine that number.
|
|
|
|
Detaching the device requires the cooperation of the domain. If the
|
|
domain fails to release the device (perhaps because the domain is hung
|
|
or is still using the device), the detach will fail.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<--force>
|
|
|
|
If this parameter is specified the device will be forcefully detached, which
|
|
may cause IO errors in the domain and possibly a guest crash
|
|
|
|
=back
|
|
|
|
|
|
|
|
=item B<block-list> I<domain-id>
|
|
|
|
List virtual block devices for a domain.
|
|
|
|
=item B<cd-insert> I<domain-id> I<virtualdevice> I<target>
|
|
|
|
Insert a cdrom into a guest domain's existing virtual cd drive. The
|
|
virtual drive must already exist but can be empty. How the device should be
|
|
presented to the guest domain is specified by the I<virtualdevice> parameter;
|
|
for example "hdc". Parameter I<target> is the target path in the backend domain
|
|
(usually domain 0) to be exported; can be a block device or a file etc.
|
|
See B<target> in L<xl-disk-configuration(5)>.
|
|
|
|
Only works with HVM domains.
|
|
|
|
|
|
=item B<cd-eject> I<domain-id> I<virtualdevice>
|
|
|
|
Eject a cdrom from a guest domain's virtual cd drive, specified by
|
|
I<virtualdevice>. Only works with HVM domains.
|
|
|
|
=back
|
|
|
|
=head2 NETWORK DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<network-attach> I<domain-id> I<network-device>
|
|
|
|
Creates a new network device in the domain specified by I<domain-id>.
|
|
I<network-device> describes the device to attach, using the same format as the
|
|
B<vif> string in the domain config file. See L<xl.cfg(5)> and
|
|
L<xl-network-configuration(5)>
|
|
for more information.
|
|
|
|
Note that only attaching PV network interfaces is supported.
|
|
|
|
=item B<network-detach> I<domain-id> I<devid|mac>
|
|
|
|
Removes the network device from the domain specified by I<domain-id>.
|
|
I<devid> is the virtual interface device number within the domain
|
|
(i.e. the 3 in vif22.3). Alternatively, the I<mac> address can be used to
|
|
select the virtual interface to detach.
|
|
|
|
=item B<network-list> I<domain-id>
|
|
|
|
List virtual network interfaces for a domain.
|
|
|
|
=back
|
|
|
|
=head2 CHANNEL DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<channel-list> I<domain-id>
|
|
|
|
List virtual channel interfaces for a domain.
|
|
|
|
=back
|
|
|
|
=head2 VIRTUAL TRUSTED PLATFORM MODULE (vTPM) DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<vtpm-attach> I<domain-id> I<vtpm-device>
|
|
|
|
Creates a new vtpm (virtual Trusted Platform Module) device in the domain
|
|
specified by I<domain-id>. I<vtpm-device> describes the device to attach,
|
|
using the same format as the B<vtpm> string in the domain config file.
|
|
See L<xl.cfg(5)> for more information.
|
|
|
|
=item B<vtpm-detach> I<domain-id> I<devid|uuid>
|
|
|
|
Removes the vtpm device from the domain specified by I<domain-id>.
|
|
I<devid> is the numeric device id given to the virtual Trusted
|
|
Platform Module device. You will need to run B<xl vtpm-list> to determine that
|
|
number. Alternatively, the I<uuid> of the vtpm can be used to
|
|
select the virtual device to detach.
|
|
|
|
=item B<vtpm-list> I<domain-id>
|
|
|
|
List virtual Trusted Platform Modules for a domain.
|
|
|
|
=back
|
|
|
|
=head2 VDISPL DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<vdispl-attach> I<domain-id> I<vdispl-device>
|
|
|
|
Creates a new vdispl device in the domain specified by I<domain-id>.
|
|
I<vdispl-device> describes the device to attach, using the same format as the
|
|
B<vdispl> string in the domain config file. See L<xl.cfg(5)> for
|
|
more information.
|
|
|
|
B<NOTES>
|
|
|
|
=over 4
|
|
|
|
As in I<vdispl-device> string semicolon is used then put quotes or escaping
|
|
when using from the shell.
|
|
|
|
B<EXAMPLE>
|
|
|
|
=over 4
|
|
|
|
xl vdispl-attach DomU connectors='id0:1920x1080;id1:800x600;id2:640x480'
|
|
|
|
or
|
|
|
|
xl vdispl-attach DomU connectors=id0:1920x1080\;id1:800x600\;id2:640x480
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=item B<vdispl-detach> I<domain-id> I<dev-id>
|
|
|
|
Removes the vdispl device specified by I<dev-id> from the domain specified by I<domain-id>.
|
|
|
|
=item B<vdispl-list> I<domain-id>
|
|
|
|
List virtual displays for a domain.
|
|
|
|
=back
|
|
|
|
=head2 VSND DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<vsnd-attach> I<domain-id> I<vsnd-item> I<vsnd-item> ...
|
|
|
|
Creates a new vsnd device in the domain specified by I<domain-id>.
|
|
I<vsnd-item>'s describe the vsnd device to attach, using the same format as the
|
|
B<VSND_ITEM_SPEC> string in the domain config file. See L<xl.cfg(5)> for
|
|
more information.
|
|
|
|
B<EXAMPLE>
|
|
|
|
=over 4
|
|
|
|
xl vsnd-attach DomU 'CARD, short-name=Main, sample-formats=s16_le;s8;u32_be'
|
|
'PCM, name=Main' 'STREAM, id=0, type=p' 'STREAM, id=1, type=c, channels-max=2'
|
|
|
|
=back
|
|
|
|
=item B<vsnd-detach> I<domain-id> I<dev-id>
|
|
|
|
Removes the vsnd device specified by I<dev-id> from the domain specified by I<domain-id>.
|
|
|
|
=item B<vsnd-list> I<domain-id>
|
|
|
|
List vsnd devices for a domain.
|
|
|
|
=back
|
|
|
|
=head2 KEYBOARD DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<vkb-attach> I<domain-id> I<vkb-device>
|
|
|
|
Creates a new keyboard device in the domain specified by I<domain-id>.
|
|
I<vkb-device> describes the device to attach, using the same format as the
|
|
B<VKB_SPEC_STRING> string in the domain config file. See L<xl.cfg(5)>
|
|
for more information.
|
|
|
|
=item B<vkb-detach> I<domain-id> I<devid>
|
|
|
|
Removes the keyboard device from the domain specified by I<domain-id>.
|
|
I<devid> is the virtual interface device number within the domain
|
|
|
|
=item B<vkb-list> I<domain-id>
|
|
|
|
List virtual network interfaces for a domain.
|
|
|
|
=back
|
|
|
|
=head1 PCI PASS-THROUGH
|
|
|
|
=over 4
|
|
|
|
=item B<pci-assignable-list> [I<-n>]
|
|
|
|
List all the B<BDF> of assignable PCI devices. See
|
|
L<xl-pci-configuration(5)> for more information. If the -n option is
|
|
specified then any name supplied when the device was made assignable
|
|
will also be displayed.
|
|
|
|
These are devices in the system which are configured to be
|
|
available for passthrough and are bound to a suitable PCI
|
|
backend driver in domain 0 rather than a real driver.
|
|
|
|
=item B<pci-assignable-add> [I<-n NAME>] I<BDF>
|
|
|
|
Make the device at B<BDF> assignable to guests. See
|
|
L<xl-pci-configuration(5)> for more information. If the -n option is
|
|
supplied then the assignable device entry will the named with the
|
|
given B<NAME>.
|
|
|
|
This will bind the device to the pciback driver and assign it to the
|
|
"quarantine domain". If it is already bound to a driver, it will
|
|
first be unbound, and the original driver stored so that it can be
|
|
re-bound to the same driver later if desired. If the device is
|
|
already bound, it will assign it to the quarantine domain and return
|
|
success.
|
|
|
|
CAUTION: This will make the device unusable by Domain 0 until it is
|
|
returned with pci-assignable-remove. Care should therefore be taken
|
|
not to do this on a device critical to domain 0's operation, such as
|
|
storage controllers, network interfaces, or GPUs that are currently
|
|
being used.
|
|
|
|
=item B<pci-assignable-remove> [I<-r>] I<BDF>|I<NAME>
|
|
|
|
Make a device non-assignable to guests. The device may be identified
|
|
either by its B<BDF> or the B<NAME> supplied when the device was made
|
|
assignable. See L<xl-pci-configuration(5)> for more information.
|
|
|
|
This will at least unbind the device from pciback, and
|
|
re-assign it from the "quarantine domain" back to domain 0. If the -r
|
|
option is specified, it will also attempt to re-bind the device to its
|
|
original driver, making it usable by Domain 0 again. If the device is
|
|
not bound to pciback, it will return success.
|
|
|
|
Note that this functionality will work even for devices which were not
|
|
made assignable by B<pci-assignable-add>. This can be used to allow
|
|
dom0 to access devices which were automatically quarantined by Xen
|
|
after domain destruction as a result of Xen's B<iommu=quarantine>
|
|
command-line default.
|
|
|
|
As always, this should only be done if you trust the guest, or are
|
|
confident that the particular device you're re-assigning to dom0 will
|
|
cancel all in-flight DMA on FLR.
|
|
|
|
=item B<pci-attach> I<domain-id> I<PCI_SPEC_STRING>
|
|
|
|
Hot-plug a new pass-through pci device to the specified domain. See
|
|
L<xl-pci-configuration(5)> for more information.
|
|
|
|
=item B<pci-detach> [I<OPTIONS>] I<domain-id> I<PCI_SPEC_STRING>
|
|
|
|
Hot-unplug a pci device that was previously passed through to a domain. See
|
|
L<xl-pci-configuration(5)> for more information.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-f>
|
|
|
|
If this parameter is specified, B<xl> is going to forcefully remove the device
|
|
even without guest domain's collaboration.
|
|
|
|
=back
|
|
|
|
=item B<pci-list> I<domain-id>
|
|
|
|
List the B<BDF> of pci devices passed through to a domain.
|
|
|
|
=back
|
|
|
|
=head1 USB PASS-THROUGH
|
|
|
|
=over 4
|
|
|
|
=item B<usbctrl-attach> I<domain-id> I<usbctrl-device>
|
|
|
|
Create a new USB controller in the domain specified by I<domain-id>,
|
|
I<usbctrl-device> describes the device to attach, using form
|
|
C<KEY=VALUE KEY=VALUE ...> where B<KEY=VALUE> has the same
|
|
meaning as the B<usbctrl> description in the domain config file.
|
|
See L<xl.cfg(5)> for more information.
|
|
|
|
=item B<usbctrl-detach> I<domain-id> I<devid>
|
|
|
|
Destroy a USB controller from the specified domain.
|
|
B<devid> is devid of the USB controller.
|
|
|
|
=item B<usbdev-attach> I<domain-id> I<usbdev-device>
|
|
|
|
Hot-plug a new pass-through USB device to the domain specified by
|
|
I<domain-id>, I<usbdev-device> describes the device to attach, using
|
|
form C<KEY=VALUE KEY=VALUE ...> where B<KEY=VALUE> has the same
|
|
meaning as the B<usbdev> description in the domain config file.
|
|
See L<xl.cfg(5)> for more information.
|
|
|
|
=item B<usbdev-detach> I<domain-id> I<controller=devid> I<port=number>
|
|
|
|
Hot-unplug a previously assigned USB device from a domain.
|
|
B<controller=devid> and B<port=number> is USB controller:port in the guest
|
|
domain the USB device is attached to.
|
|
|
|
=item B<usb-list> I<domain-id>
|
|
|
|
List pass-through usb devices for a domain.
|
|
|
|
=back
|
|
|
|
=head1 DEVICE-MODEL CONTROL
|
|
|
|
=over 4
|
|
|
|
=item B<qemu-monitor-command> I<domain-id> I<command>
|
|
|
|
Issue a monitor command to the device model of the domain specified by
|
|
I<domain-id>. I<command> can be any valid command qemu understands. This
|
|
can be e.g. used to add non-standard devices or devices with non-standard
|
|
parameters to a domain. The output of the command is printed to stdout.
|
|
|
|
B<Warning:> This qemu monitor access is provided for convenience when
|
|
debugging, troubleshooting, and experimenting. Its use is not
|
|
supported by the Xen Project.
|
|
|
|
Specifically, not all information displayed by the qemu monitor will
|
|
necessarily be accurate or complete, because in a Xen system qemu
|
|
does not have a complete view of the guest.
|
|
|
|
Furthermore, modifying the guest's setup via the qemu monitor may
|
|
conflict with the Xen toolstack's assumptions. Resulting problems
|
|
may include, but are not limited to: guest crashes; toolstack error
|
|
messages; inability to migrate the guest; and security
|
|
vulnerabilities which are not covered by the Xen Project security
|
|
response policy.
|
|
|
|
B<EXAMPLE>
|
|
|
|
Obtain information of USB devices connected as such via the device model
|
|
(only!) to a domain:
|
|
|
|
xl qemu-monitor-command vm1 'info usb'
|
|
Device 0.2, Port 5, Speed 480 Mb/s, Product Mass Storage
|
|
|
|
=back
|
|
|
|
=head1 FLASK
|
|
|
|
B<FLASK> is a security framework that defines a mandatory access control policy
|
|
providing fine-grained controls over Xen domains, allowing the policy writer
|
|
to define what interactions between domains, devices, and the hypervisor are
|
|
permitted. Some example of what you can do using XSM/FLASK:
|
|
- Prevent two domains from communicating via event channels or grants
|
|
- Control which domains can use device passthrough (and which devices)
|
|
- Restrict or audit operations performed by privileged domains
|
|
- Prevent a privileged domain from arbitrarily mapping pages from other
|
|
domains.
|
|
|
|
You can find more details on how to use FLASK and an example security
|
|
policy here: L<https://xenbits.xenproject.org/docs/unstable/misc/xsm-flask.txt>
|
|
|
|
=over 4
|
|
|
|
=item B<getenforce>
|
|
|
|
Determine if the FLASK security module is loaded and enforcing its policy.
|
|
|
|
=item B<setenforce> I<1|0|Enforcing|Permissive>
|
|
|
|
Enable or disable enforcing of the FLASK access controls. The default is
|
|
permissive, but this can be changed to enforcing by specifying "flask=enforcing"
|
|
or "flask=late" on the hypervisor's command line.
|
|
|
|
=item B<loadpolicy> I<policy-file>
|
|
|
|
Load FLASK policy from the given policy file. The initial policy is provided to
|
|
the hypervisor as a multiboot module; this command allows runtime updates to the
|
|
policy. Loading new security policy will reset runtime changes to device labels.
|
|
|
|
=back
|
|
|
|
=head1 PLATFORM SHARED RESOURCE MONITORING/CONTROL
|
|
|
|
Intel Haswell and later server platforms offer shared resource monitoring
|
|
and control technologies. The availability of these technologies and the
|
|
hardware capabilities can be shown with B<psr-hwinfo>.
|
|
|
|
See L<https://xenbits.xenproject.org/docs/unstable/misc/xl-psr.html> for more
|
|
information.
|
|
|
|
=over 4
|
|
|
|
=item B<psr-hwinfo> [I<OPTIONS>]
|
|
|
|
Show Platform Shared Resource (PSR) hardware information.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-m>, B<--cmt>
|
|
|
|
Show Cache Monitoring Technology (CMT) hardware information.
|
|
|
|
=item B<-a>, B<--cat>
|
|
|
|
Show Cache Allocation Technology (CAT) hardware information.
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=head2 CACHE MONITORING TECHNOLOGY
|
|
|
|
Intel Haswell and later server platforms offer monitoring capability in each
|
|
logical processor to measure specific platform shared resource metric, for
|
|
example, L3 cache occupancy. In the Xen implementation, the monitoring
|
|
granularity is domain level. To monitor a specific domain, just attach the
|
|
domain id with the monitoring service. When the domain doesn't need to be
|
|
monitored any more, detach the domain id from the monitoring service.
|
|
|
|
Intel Broadwell and later server platforms also offer total/local memory
|
|
bandwidth monitoring. Xen supports per-domain monitoring for these two
|
|
additional monitoring types. Both memory bandwidth monitoring and L3 cache
|
|
occupancy monitoring share the same set of underlying monitoring service. Once
|
|
a domain is attached to the monitoring service, monitoring data can be shown
|
|
for any of these monitoring types.
|
|
|
|
There is no cache monitoring and memory bandwidth monitoring on L2 cache so
|
|
far.
|
|
|
|
=over 4
|
|
|
|
=item B<psr-cmt-attach> I<domain-id>
|
|
|
|
attach: Attach the platform shared resource monitoring service to a domain.
|
|
|
|
=item B<psr-cmt-detach> I<domain-id>
|
|
|
|
detach: Detach the platform shared resource monitoring service from a domain.
|
|
|
|
=item B<psr-cmt-show> I<psr-monitor-type> [I<domain-id>]
|
|
|
|
Show monitoring data for a certain domain or all domains. Current supported
|
|
monitor types are:
|
|
- "cache-occupancy": showing the L3 cache occupancy(KB).
|
|
- "total-mem-bandwidth": showing the total memory bandwidth(KB/s).
|
|
- "local-mem-bandwidth": showing the local memory bandwidth(KB/s).
|
|
|
|
=back
|
|
|
|
=head2 CACHE ALLOCATION TECHNOLOGY
|
|
|
|
Intel Broadwell and later server platforms offer capabilities to configure and
|
|
make use of the Cache Allocation Technology (CAT) mechanisms, which enable more
|
|
cache resources (i.e. L3/L2 cache) to be made available for high priority
|
|
applications. In the Xen implementation, CAT is used to control cache allocation
|
|
on VM basis. To enforce cache on a specific domain, just set capacity bitmasks
|
|
(CBM) for the domain.
|
|
|
|
Intel Broadwell and later server platforms also offer Code/Data Prioritization
|
|
(CDP) for cache allocations, which support specifying code or data cache for
|
|
applications. CDP is used on a per VM basis in the Xen implementation. To
|
|
specify code or data CBM for the domain, CDP feature must be enabled and CBM
|
|
type options need to be specified when setting CBM, and the type options (code
|
|
and data) are mutually exclusive. There is no CDP support on L2 so far.
|
|
|
|
=over 4
|
|
|
|
=item B<psr-cat-set> [I<OPTIONS>] I<domain-id> I<cbm>
|
|
|
|
Set cache capacity bitmasks(CBM) for a domain. For how to specify I<cbm>
|
|
please refer to L<https://xenbits.xenproject.org/docs/unstable/misc/xl-psr.html>.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-s SOCKET>, B<--socket=SOCKET>
|
|
|
|
Specify the socket to process, otherwise all sockets are processed.
|
|
|
|
=item B<-l LEVEL>, B<--level=LEVEL>
|
|
|
|
Specify the cache level to process, otherwise the last level cache (L3) is
|
|
processed.
|
|
|
|
=item B<-c>, B<--code>
|
|
|
|
Set code CBM when CDP is enabled.
|
|
|
|
=item B<-d>, B<--data>
|
|
|
|
Set data CBM when CDP is enabled.
|
|
|
|
=back
|
|
|
|
=item B<psr-cat-show> [I<OPTIONS>] [I<domain-id>]
|
|
|
|
Show CAT settings for a certain domain or all domains.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-l LEVEL>, B<--level=LEVEL>
|
|
|
|
Specify the cache level to process, otherwise the last level cache (L3) is
|
|
processed.
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=head2 Memory Bandwidth Allocation
|
|
|
|
Intel Skylake and later server platforms offer capabilities to configure and
|
|
make use of the Memory Bandwidth Allocation (MBA) mechanisms, which provides
|
|
OS/VMMs the ability to slow misbehaving apps/VMs by using a credit-based
|
|
throttling mechanism. In the Xen implementation, MBA is used to control memory
|
|
bandwidth on VM basis. To enforce bandwidth on a specific domain, just set
|
|
throttling value (THRTL) for the domain.
|
|
|
|
=over 4
|
|
|
|
=item B<psr-mba-set> [I<OPTIONS>] I<domain-id> I<thrtl>
|
|
|
|
Set throttling value (THRTL) for a domain. For how to specify I<thrtl>
|
|
please refer to L<https://xenbits.xenproject.org/docs/unstable/misc/xl-psr.html>.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-s SOCKET>, B<--socket=SOCKET>
|
|
|
|
Specify the socket to process, otherwise all sockets are processed.
|
|
|
|
=back
|
|
|
|
=item B<psr-mba-show> [I<domain-id>]
|
|
|
|
Show MBA settings for a certain domain or all domains. For linear mode, it
|
|
shows the decimal value. For non-linear mode, it shows hexadecimal value.
|
|
|
|
=back
|
|
|
|
=head1 IGNORED FOR COMPATIBILITY WITH XM
|
|
|
|
xl is mostly command-line compatible with the old xm utility used with
|
|
the old Python xend. For compatibility, the following options are
|
|
ignored:
|
|
|
|
=over 4
|
|
|
|
=item B<xl migrate --live>
|
|
|
|
=back
|
|
|
|
=head1 ENVIRONMENT VARIABLES
|
|
|
|
The following environment variables shall affect the execution of xl:
|
|
|
|
=over 4
|
|
|
|
=item LIBXL_BOOTLOADER_RESTRICT
|
|
|
|
Equivalent to L<xl.cfg(5)> B<bootloader_restrict> option. Provided for
|
|
compatibility reasons. Having this variable set is equivalent to enabling
|
|
the option, even if the value is 0.
|
|
|
|
If set takes precedence over L<xl.cfg(5)> and L<xl.conf(5)>
|
|
B<bootloader_restrict> options.
|
|
|
|
=item LIBXL_BOOTLOADER_USER
|
|
|
|
Equivalent to L<xl.cfg(5)> B<bootloader_user> option. Provided for
|
|
compatibility reasons.
|
|
|
|
If set takes precedence over L<xl.cfg(5)> B<bootloader_user> option.
|
|
|
|
=item LIBXL_BOOTLOADER_TIMEOUT
|
|
|
|
Timeout in seconds for bootloader execution when running in restricted mode.
|
|
Otherwise the build time default in LIBXL_BOOTLOADER_TIMEOUT will be used.
|
|
|
|
If defined the value must be an unsigned integer between 0 and INT_MAX,
|
|
otherwise behavior is undefined. Setting to 0 disables the timeout.
|
|
|
|
=back
|
|
|
|
=head1 SEE ALSO
|
|
|
|
The following man pages:
|
|
|
|
L<xl.cfg(5)>, L<xlcpupool.cfg(5)>, L<xentop(1)>, L<xl-disk-configuration(5)>
|
|
L<xl-network-configuration(5)>
|
|
|
|
And the following documents on the xenproject.org website:
|
|
|
|
L<https://xenbits.xenproject.org/docs/unstable/misc/xsm-flask.txt>
|
|
L<https://xenbits.xenproject.org/docs/unstable/misc/xl-psr.html>
|
|
|
|
For systems that don't automatically bring the CPU online:
|
|
|
|
L<https://wiki.xenproject.org/wiki/Paravirt_Linux_CPU_Hotplug>
|
|
|
|
=head1 BUGS
|
|
|
|