mirror of
https://github.com/xen-project/xen.git
synced 2026-10-29 18:50:05 +01:00
in fact, right now, xl sub-commands 'cpupool-cpu-add' and 'cpupool-cpu-remove' only accept the specification of one pCPU to be added or removed to/from a cpupool. With this change, they can deal with ranges, like "4-8", or "node:1,12-18,^14". The syntax is exactly the same one that is supported by the 'vcpu-pin' subcommand, and specifying just one pCPU still works, of course. This make things more flexible, more consistent, and also improves error handling, as the pCPU range parsing routine already present in xl is more reliable than just a call to atoi(). Signed-off-by: Dario Faggioli <dario.faggioli@citrix.com> Cc: Ian Campbell <ian.campbell@citrix.com> Cc: Ian Jackson <Ian.Jackson@eu.citrix.com> Cc: Stefano Stabellini <stefano.stabellini@eu.citrix.com> Cc: Wei Liu <wei.liu2@citrix.com> Cc: Juergen Gross <JGross@suse.com> Acked-by: Wei Liu <wei.liu2@citrix.com>
1548 lines
43 KiB
Groff
1548 lines
43 KiB
Groff
=head1 NAME
|
|
|
|
XL - Xen management tool, based on LibXenlight
|
|
|
|
=head1 SYNOPSIS
|
|
|
|
B<xl> I<subcommand> [I<args>]
|
|
|
|
=head1 DESCRIPTION
|
|
|
|
The B<xl> program is the new tool for managing Xen guest
|
|
domains. The program can be used to create, pause, and shutdown
|
|
domains. It can also be used to list current domains, enable or pin
|
|
VCPUs, and attach or detach virtual block devices.
|
|
|
|
The basic structure of every B<xl> command is almost always:
|
|
|
|
=over 2
|
|
|
|
B<xl> I<subcommand> [I<OPTIONS>] I<domain-id>
|
|
|
|
=back
|
|
|
|
Where I<subcommand> is one of the subcommands listed below, I<domain-id>
|
|
is the numeric domain id, or the domain name (which will be internally
|
|
translated to domain id), and I<OPTIONS> are subcommand specific
|
|
options. There are a few exceptions to this rule in the cases where
|
|
the subcommand in question acts on all domains, the entire machine,
|
|
or directly on the Xen hypervisor. Those exceptions will be clear for
|
|
each of those subcommands.
|
|
|
|
=head1 NOTES
|
|
|
|
=over 4
|
|
|
|
=item start the script B</etc/init.d/xencommons> at boot time
|
|
|
|
Most B<xl> operations rely upon B<xenstored> and B<xenconsoled>: make
|
|
sure you start the script B</etc/init.d/xencommons> at boot time to
|
|
initialize all the daemons needed by B<xl>.
|
|
|
|
=item setup a B<xenbr0> bridge in dom0
|
|
|
|
In the most common network configuration, you need to setup a bridge in dom0
|
|
named B<xenbr0> in order to have a working network in the guest domains.
|
|
Please refer to the documentation of your Linux distribution to know how to
|
|
setup the bridge.
|
|
|
|
=item B<autoballoon>
|
|
|
|
If you specify the amount of memory dom0 has, passing B<dom0_mem> to
|
|
Xen, it is highly recommended to disable B<autoballoon>. Edit
|
|
B</etc/xen/xl.conf> and set it to 0.
|
|
|
|
=item run xl as B<root>
|
|
|
|
Most B<xl> commands require root privileges to run due to the
|
|
communications channels used to talk to the hypervisor. Running as
|
|
non root will return an error.
|
|
|
|
=back
|
|
|
|
=head1 GLOBAL OPTIONS
|
|
|
|
Some global options are always available:
|
|
|
|
=over 4
|
|
|
|
=item B<-v>
|
|
|
|
Verbose.
|
|
|
|
=item B<-N>
|
|
|
|
Dry run: do not actually execute the command.
|
|
|
|
=item B<-f>
|
|
|
|
Force execution: xl will refuse to run some commands if it detects that xend is
|
|
also running, this option will force the execution of those commands, even
|
|
though it is unsafe.
|
|
|
|
=item B<-t>
|
|
|
|
Always use carriage-return-based overwriting for printing progress
|
|
messages without scrolling the screen. Without -t, this is done only
|
|
if stderr is a tty.
|
|
|
|
=back
|
|
|
|
=head1 DOMAIN SUBCOMMANDS
|
|
|
|
The following subcommands manipulate domains directly. As stated
|
|
previously, most commands take I<domain-id> as the first parameter.
|
|
|
|
=over 4
|
|
|
|
=item B<button-press> I<domain-id> I<button>
|
|
|
|
I<This command is deprecated. Please use C<xl trigger> in preference>
|
|
|
|
Indicate an ACPI button press to the domain. I<button> is may be 'power' or
|
|
'sleep'. This command is only available for HVM domains.
|
|
|
|
=item B<create> [I<configfile>] [I<OPTIONS>]
|
|
|
|
The create subcommand takes a config file as first argument: see
|
|
L<xl.cfg> for full details of that file format and possible options.
|
|
If I<configfile> is missing B<XL> creates the domain starting from the
|
|
default value for every option.
|
|
|
|
I<configfile> has to be an absolute path to a file.
|
|
|
|
Create will return B<as soon> as the domain is started. This B<does
|
|
not> mean the guest OS in the domain has actually booted, or is
|
|
available for input.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-q>, B<--quiet>
|
|
|
|
No console output.
|
|
|
|
=item B<-f=FILE>, B<--defconfig=FILE>
|
|
|
|
Use the given configuration file.
|
|
|
|
=item B<-p>
|
|
|
|
Leave the domain paused after it is created.
|
|
|
|
=item B<-V>, B<--vncviewer>
|
|
|
|
Attach to domain's VNC server, forking a vncviewer process.
|
|
|
|
=item B<-A>, B<--vncviewer-autopass>
|
|
|
|
Pass VNC password to vncviewer via stdin.
|
|
|
|
=item B<-c>
|
|
|
|
Attach console to the domain as soon as it has started. This is
|
|
useful for determining issues with crashing domains and just as a
|
|
general convenience since you often want to watch the
|
|
domain boot.
|
|
|
|
=item B<key=value>
|
|
|
|
It is possible to pass I<key=value> pairs on the command line to provide
|
|
options as if they were written in the configuration file; these override
|
|
whatever is in the I<configfile>.
|
|
|
|
NB: Many config options require characters such as quotes or brackets
|
|
which are interpreted by the shell (and often discarded) before being
|
|
passed to xl, resulting in xl being unable to parse the value
|
|
correctly. A simple work-around is to put all extra options within a
|
|
single set of quotes, separated by semicolons. (See below for an example.)
|
|
|
|
=back
|
|
|
|
B<EXAMPLES>
|
|
|
|
=over 4
|
|
|
|
=item I<with config file>
|
|
|
|
xl create DebianLenny
|
|
|
|
This creates a domain with the file /etc/xen/DebianLenny, and returns as
|
|
soon as it is run.
|
|
|
|
=item I<with extra parameters>
|
|
|
|
xl create hvm.cfg 'cpus="0-3"; pci=["01:05.1","01:05.2"]'
|
|
|
|
This creates a domain with the file hvm.cfg, but additionally pins it to
|
|
cpus 0-3, and passes through two PCI devices.
|
|
|
|
=back
|
|
|
|
=item B<config-update> B<domid> [I<configfile>] [I<OPTIONS>]
|
|
|
|
Update the saved configuration for a running domain. This has no
|
|
immediate effect but will be applied when the guest is next
|
|
restarted. This command is useful to ensure that runtime modifications
|
|
made to the guest will be preserved when the guest is restarted.
|
|
|
|
Since Xen 4.5 xl has improved capabilities to handle dynamic domain
|
|
configuration changes and will preserve any changes made a runtime
|
|
when necessary. Therefore it should not normally be necessary to use
|
|
this command any more.
|
|
|
|
I<configfile> has to be an absolute path to a file.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-f=FILE>, B<--defconfig=FILE>
|
|
|
|
Use the given configuration file.
|
|
|
|
=item B<key=value>
|
|
|
|
It is possible to pass I<key=value> pairs on the command line to
|
|
provide options as if they were written in the configuration file;
|
|
these override whatever is in the I<configfile>. Please see the note
|
|
under I<create> on handling special characters when passing
|
|
I<key=value> pairs on the command line.
|
|
|
|
=back
|
|
|
|
=item B<console> [I<OPTIONS>] I<domain-id>
|
|
|
|
Attach to domain I<domain-id>'s console. If you've set up your domains to
|
|
have a traditional log in console this will look much like a normal
|
|
text log in screen.
|
|
|
|
Use the key combination Ctrl+] to detach the domain console.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<-t [pv|serial]>
|
|
|
|
Connect to a PV console or connect to an emulated serial console.
|
|
PV consoles are the only consoles available for PV domains while HVM
|
|
domains can have both. If this option is not specified it defaults to
|
|
emulated serial for HVM guests and PV console for PV guests.
|
|
|
|
=item I<-n NUM>
|
|
|
|
Connect to console number I<NUM>. Console numbers start from 0.
|
|
|
|
=back
|
|
|
|
=item B<destroy> [I<OPTIONS>] I<domain-id>
|
|
|
|
Immediately terminate the domain I<domain-id>. This doesn't give the
|
|
domain OS any chance to react, and is the equivalent of ripping the
|
|
power cord out on a physical machine. In most cases you will want to
|
|
use the B<shutdown> command instead.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<-f>
|
|
|
|
Allow domain 0 to be destroyed. Because domain cannot destroy itself, this is
|
|
only possible when using a disaggregated toolstack, and is most useful when
|
|
using a hardware domain separated from domain 0.
|
|
|
|
=back
|
|
|
|
=item B<domid> I<domain-name>
|
|
|
|
Converts a domain name to a domain id.
|
|
|
|
=item B<domname> I<domain-id>
|
|
|
|
Converts a domain id to a domain name.
|
|
|
|
=item B<rename> I<domain-id> I<new-name>
|
|
|
|
Change the domain name of I<domain-id> to I<new-name>.
|
|
|
|
=item B<dump-core> I<domain-id> [I<filename>]
|
|
|
|
Dumps the virtual machine's memory for the specified domain to the
|
|
I<filename> specified, without pausing the domain. The dump file will
|
|
be written to a distribution specific directory for dump files. Such
|
|
as: /var/lib/xen/dump or /var/xen/dump.
|
|
|
|
=item B<help> [I<--long>]
|
|
|
|
Displays the short help message (i.e. common commands).
|
|
|
|
The I<--long> option prints out the complete set of B<xl> subcommands,
|
|
grouped by function.
|
|
|
|
=item B<list> [I<OPTIONS>] [I<domain-id> ...]
|
|
|
|
Prints information about one or more domains. If no domains are
|
|
specified it prints out information about all domains.
|
|
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-l>, B<--long>
|
|
|
|
The output for B<xl list> is not the table view shown below, but
|
|
instead presents the data in as a JSON data structure.
|
|
|
|
=item B<-Z>, B<--context>
|
|
Also prints the security labels.
|
|
|
|
=item B<-v>, B<--verbose>
|
|
|
|
Also prints the domain UUIDs, the shutdown reason and security labels.
|
|
|
|
=item B<-c>, <--cpupool>
|
|
|
|
Also prints the cpupool the domain belong to.
|
|
|
|
=item B<-n>, <--numa>
|
|
|
|
Also prints the domain NUMA node affinity.
|
|
|
|
=back
|
|
|
|
B<EXAMPLE>
|
|
|
|
An example format for the list is as follows:
|
|
|
|
Name ID Mem VCPUs State Time(s)
|
|
Domain-0 0 750 4 r----- 11794.3
|
|
win 1 1019 1 r----- 0.3
|
|
linux 2 2048 2 r----- 5624.2
|
|
|
|
Name is the name of the domain. ID the numeric domain id. Mem is the
|
|
desired amount of memory to allocate to the domain (although it may
|
|
not be the currently allocated amount). VCPUs is the number of
|
|
virtual CPUs allocated to the domain. State is the run state (see
|
|
below). Time is the total run time of the domain as accounted for by
|
|
Xen.
|
|
|
|
B<STATES>
|
|
|
|
The State field lists 6 states for a Xen domain, and which ones the
|
|
current domain is in.
|
|
|
|
=over 4
|
|
|
|
=item B<r - running>
|
|
|
|
The domain is currently running on a CPU.
|
|
|
|
=item B<b - blocked>
|
|
|
|
The domain is blocked, and not running or runnable. This can be caused
|
|
because the domain is waiting on IO (a traditional wait state) or has
|
|
gone to sleep because there was nothing else for it to do.
|
|
|
|
=item B<p - paused>
|
|
|
|
The domain has been paused, usually occurring through the administrator
|
|
running B<xl pause>. When in a paused state the domain will still
|
|
consume allocated resources like memory, but will not be eligible for
|
|
scheduling by the Xen hypervisor.
|
|
|
|
=item B<s - shutdown>
|
|
|
|
The guest OS has shut down (SCHEDOP_shutdown has been called) but the
|
|
domain is not dying yet.
|
|
|
|
=item B<c - crashed>
|
|
|
|
The domain has crashed, which is always a violent ending. Usually
|
|
this state can only occur if the domain has been configured not to
|
|
restart on crash. See L<xl.cfg(5)> for more info.
|
|
|
|
=item B<d - dying>
|
|
|
|
The domain is in process of dying, but hasn't completely shutdown or
|
|
crashed.
|
|
|
|
=back
|
|
|
|
B<NOTES>
|
|
|
|
=over 4
|
|
|
|
The Time column is deceptive. Virtual IO (network and block devices)
|
|
used by domains requires coordination by Domain0, which means that
|
|
Domain0 is actually charged for much of the time that a DomainU is
|
|
doing IO. Use of this time value to determine relative utilizations
|
|
by domains is thus very suspect, as a high IO workload may show as
|
|
less utilized than a high CPU workload. Consider yourself warned.
|
|
|
|
=back
|
|
|
|
=item B<mem-max> I<domain-id> I<mem>
|
|
|
|
Specify the maximum amount of memory the domain is able to use, appending 't'
|
|
for terabytes, 'g' for gigabytes, 'm' for megabytes, 'k' for kilobytes and 'b'
|
|
for bytes.
|
|
|
|
The mem-max value may not correspond to the actual memory used in the
|
|
domain, as it may balloon down its memory to give more back to the OS.
|
|
|
|
=item B<mem-set> I<domain-id> I<mem>
|
|
|
|
Set the domain's used memory using the balloon driver; append 't' for
|
|
terabytes, 'g' for gigabytes, 'm' for megabytes, 'k' for kilobytes and 'b' for
|
|
bytes.
|
|
|
|
Because this operation requires cooperation from the domain operating
|
|
system, there is no guarantee that it will succeed. This command will
|
|
definitely not work unless the domain has the required paravirt
|
|
driver.
|
|
|
|
B<Warning:> There is no good way to know in advance how small of a
|
|
mem-set will make a domain unstable and cause it to crash. Be very
|
|
careful when using this command on running domains.
|
|
|
|
=item B<migrate> [I<OPTIONS>] I<domain-id> I<host>
|
|
|
|
Migrate a domain to another host machine. By default B<xl> relies on ssh as a
|
|
transport mechanism between the two hosts.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-s> I<sshcommand>
|
|
|
|
Use <sshcommand> instead of ssh. String will be passed to sh. If empty, run
|
|
<host> instead of ssh <host> xl migrate-receive [-d -e].
|
|
|
|
=item B<-e>
|
|
|
|
On the new host, do not wait in the background (on <host>) for the death of the
|
|
domain. See the corresponding option of the I<create> subcommand.
|
|
|
|
=item B<-C> I<config>
|
|
|
|
Send <config> instead of config file from creation.
|
|
|
|
=item B<--debug>
|
|
|
|
Print huge (!) amount of debug during the migration process.
|
|
|
|
=back
|
|
|
|
=item B<remus> [I<OPTIONS>] I<domain-id> I<host>
|
|
|
|
Enable Remus HA for domain. By default B<xl> relies on ssh as a transport
|
|
mechanism between the two hosts.
|
|
|
|
N.B: Remus support in xl is still in experimental (proof-of-concept) phase.
|
|
Disk replication support is limited to DRBD disks.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-i> I<MS>
|
|
|
|
Checkpoint domain memory every MS milliseconds (default 200ms).
|
|
|
|
=item B<-u>
|
|
|
|
Disable memory checkpoint compression.
|
|
|
|
=item B<-s> I<sshcommand>
|
|
|
|
Use <sshcommand> instead of ssh. String will be passed to sh.
|
|
If empty, run <host> instead of ssh <host> xl migrate-receive -r [-e].
|
|
|
|
=item B<-e>
|
|
|
|
On the new host, do not wait in the background (on <host>) for the death
|
|
of the domain. See the corresponding option of the I<create> subcommand.
|
|
|
|
=item B<-N> I<netbufscript>
|
|
|
|
Use <netbufscript> to setup network buffering instead of the
|
|
default script (/etc/xen/scripts/remus-netbuf-setup).
|
|
|
|
=item B<-F>
|
|
|
|
Run Remus in unsafe mode. Use this option with caution as failover may
|
|
not work as intended.
|
|
|
|
=item B<-b>
|
|
|
|
Replicate memory checkpoints to /dev/null (blackhole).
|
|
Generally useful for debugging. Requires enabling unsafe mode.
|
|
|
|
=item B<-n>
|
|
|
|
Disable network output buffering. Requires enabling unsafe mode.
|
|
|
|
=item B<-d>
|
|
|
|
Disable disk replication. Requires enabling unsafe mode.
|
|
|
|
=back
|
|
|
|
=item B<pause> I<domain-id>
|
|
|
|
Pause a domain. When in a paused state the domain will still consume
|
|
allocated resources such as memory, but will not be eligible for
|
|
scheduling by the Xen hypervisor.
|
|
|
|
=item B<reboot> [I<OPTIONS>] I<domain-id>
|
|
|
|
Reboot a domain. This acts just as if the domain had the B<reboot>
|
|
command run from the console. The command returns as soon as it has
|
|
executed the reboot action, which may be significantly before the
|
|
domain actually reboots.
|
|
|
|
For HVM domains this requires PV drivers to be installed in your guest
|
|
OS. If PV drivers are not present but you have configured the guest OS
|
|
to behave appropriately you may be able to use the I<-F> option
|
|
trigger a reset button press.
|
|
|
|
The behavior of what happens to a domain when it reboots is set by the
|
|
B<on_reboot> parameter of the domain configuration file when the
|
|
domain was created.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-F>
|
|
|
|
If the guest does not support PV reboot control then fallback to
|
|
sending an ACPI power event (equivalent to the I<reset> option to
|
|
I<trigger>.
|
|
|
|
You should ensure that the guest is configured to behave as expected
|
|
in response to this event.
|
|
|
|
=back
|
|
|
|
=item B<restore> [I<OPTIONS>] [I<ConfigFile>] I<CheckpointFile>
|
|
|
|
Build a domain from an B<xl save> state file. See B<save> for more info.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-p>
|
|
|
|
Do not unpause domain after restoring it.
|
|
|
|
=item B<-e>
|
|
|
|
Do not wait in the background for the death of the domain on the new host.
|
|
See the corresponding option of the I<create> subcommand.
|
|
|
|
=item B<-d>
|
|
|
|
Enable debug messages.
|
|
|
|
=item B<-V>, B<--vncviewer>
|
|
|
|
Attach to domain's VNC server, forking a vncviewer process.
|
|
|
|
=item B<-A>, B<--vncviewer-autopass>
|
|
|
|
Pass VNC password to vncviewer via stdin.
|
|
|
|
|
|
|
|
=back
|
|
|
|
=item B<save> [I<OPTIONS>] I<domain-id> I<CheckpointFile> [I<ConfigFile>]
|
|
|
|
Saves a running domain to a state file so that it can be restored
|
|
later. Once saved, the domain will no longer be running on the
|
|
system, unless the -c or -p options are used.
|
|
B<xl restore> restores from this checkpoint file.
|
|
Passing a config file argument allows the user to manually select the VM config
|
|
file used to create the domain.
|
|
|
|
=over 4
|
|
|
|
=item B<-c>
|
|
|
|
Leave domain running after creating the snapshot.
|
|
|
|
=item B<-p>
|
|
|
|
Leave domain paused after creating the snapshot.
|
|
|
|
=back
|
|
|
|
=item B<sharing> [I<domain-id>]
|
|
|
|
List count of shared pages.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<domain_id>
|
|
|
|
List specifically for that domain. Otherwise, list for all domains.
|
|
|
|
=back
|
|
|
|
=item B<shutdown> [I<OPTIONS>] I<-a|domain-id>
|
|
|
|
Gracefully shuts down a domain. This coordinates with the domain OS
|
|
to perform graceful shutdown, so there is no guarantee that it will
|
|
succeed, and may take a variable length of time depending on what
|
|
services must be shutdown in the domain.
|
|
|
|
For HVM domains this requires PV drivers to be installed in your guest
|
|
OS. If PV drivers are not present but you have configured the guest OS
|
|
to behave appropriately you may be able to use the I<-F> option
|
|
trigger a power button press.
|
|
|
|
The command returns immediately after signally the domain unless that
|
|
B<-w> flag is used.
|
|
|
|
The behavior of what happens to a domain when it reboots is set by the
|
|
B<on_shutdown> parameter of the domain configuration file when the
|
|
domain was created.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-a>, B<--all>
|
|
|
|
Shutdown all guest domains. Often used when doing a complete shutdown
|
|
of a Xen system.
|
|
|
|
=item B<-w>, B<--wait>
|
|
|
|
Wait for the domain to complete shutdown before returning.
|
|
|
|
=item B<-F>
|
|
|
|
If the guest does not support PV shutdown control then fallback to
|
|
sending an ACPI power event (equivalent to the I<power> option to
|
|
I<trigger>.
|
|
|
|
You should ensure that the guest is configured to behave as expected
|
|
in response to this event.
|
|
|
|
=back
|
|
|
|
=item B<sysrq> I<domain-id> I<letter>
|
|
|
|
Send a <Magic System Request> to the domain, each type of request is
|
|
represented by a different letter.
|
|
It can be used to send SysRq requests to Linux guests, see sysrq.txt in
|
|
your Linux Kernel sources for more information.
|
|
It requires PV drivers to be installed in your guest OS.
|
|
|
|
=item B<trigger> I<domain-id> I<nmi|reset|init|power|sleep|s3resume> [I<VCPU>]
|
|
|
|
Send a trigger to a domain, where the trigger can be: nmi, reset, init, power
|
|
or sleep. Optionally a specific vcpu number can be passed as an argument.
|
|
This command is only available for HVM domains.
|
|
|
|
=item B<unpause> I<domain-id>
|
|
|
|
Moves a domain out of the paused state. This will allow a previously
|
|
paused domain to now be eligible for scheduling by the Xen hypervisor.
|
|
|
|
=item B<vcpu-set> I<domain-id> I<vcpu-count>
|
|
|
|
Enables the I<vcpu-count> virtual CPUs for the domain in question.
|
|
Like mem-set, this command can only allocate up to the maximum virtual
|
|
CPU count configured at boot for the domain.
|
|
|
|
If the I<vcpu-count> is smaller than the current number of active
|
|
VCPUs, the highest number VCPUs will be hotplug removed. This may be
|
|
important for pinning purposes.
|
|
|
|
Attempting to set the VCPUs to a number larger than the initially
|
|
configured VCPU count is an error. Trying to set VCPUs to < 1 will be
|
|
quietly ignored.
|
|
|
|
Some guests may need to actually bring the newly added CPU online
|
|
after B<vcpu-set>, go to B<SEE ALSO> section for information.
|
|
|
|
=item B<vcpu-list> [I<domain-id>]
|
|
|
|
Lists VCPU information for a specific domain. If no domain is
|
|
specified, VCPU information for all domains will be provided.
|
|
|
|
=item B<vcpu-pin> I<domain-id> I<vcpu> I<cpus hard> I<cpus soft>
|
|
|
|
Set hard and soft affinity for a I<vcpu> of <domain-id>. Normally VCPUs
|
|
can float between available CPUs whenever Xen deems a different run state
|
|
is appropriate.
|
|
|
|
Hard affinity can be used to restrict this, by ensuring certain VCPUs
|
|
can only run on certain physical CPUs. Soft affinity specifies a I<preferred>
|
|
set of CPUs. Soft affinity needs special support in the scheduler, which is
|
|
only provided in credit1.
|
|
|
|
The keyword B<all> can be used to apply the hard and soft affinity masks to
|
|
all the VCPUs in the domain. The symbol '-' can be used to leave either
|
|
hard or soft affinity alone.
|
|
|
|
For example:
|
|
|
|
xl vcpu-pin 0 3 - 6-9
|
|
|
|
will set soft affinity for vCPU 3 of domain 0 to pCPUs 6,7,8 and 9,
|
|
leaving its hard affinity untouched. On the othe hand:
|
|
|
|
xl vcpu-pin 0 3 3,4 6-9
|
|
|
|
will set both hard and soft affinity, the former to pCPUs 3 and 4, the
|
|
latter to pCPUs 6,7,8, and 9.
|
|
|
|
=item B<vm-list>
|
|
|
|
Prints information about guests. This list excludes information about
|
|
service or auxiliary domains such as dom0 and stubdoms.
|
|
|
|
B<EXAMPLE>
|
|
|
|
An example format for the list is as follows:
|
|
|
|
UUID ID name
|
|
59e1cf6c-6ab9-4879-90e7-adc8d1c63bf5 2 win
|
|
50bc8f75-81d0-4d53-b2e6-95cb44e2682e 3 linux
|
|
|
|
=item B<vncviewer> [I<OPTIONS>] I<domain-id>
|
|
|
|
Attach to domain's VNC server, forking a vncviewer process.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<--autopass>
|
|
|
|
Pass VNC password to vncviewer via stdin.
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=head1 XEN HOST SUBCOMMANDS
|
|
|
|
=over 4
|
|
|
|
=item B<debug-keys> I<keys>
|
|
|
|
Send debug I<keys> to Xen. It is the same as pressing the Xen
|
|
"conswitch" (Ctrl-A by default) three times and then pressing "keys".
|
|
|
|
=item B<dmesg> [B<-c>]
|
|
|
|
Reads the Xen message buffer, similar to dmesg on a Linux system. The
|
|
buffer contains informational, warning, and error messages created
|
|
during Xen's boot process. If you are having problems with Xen, this
|
|
is one of the first places to look as part of problem determination.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-c>, B<--clear>
|
|
|
|
Clears Xen's message buffer.
|
|
|
|
=back
|
|
|
|
=item B<info> [B<-n>, B<--numa>]
|
|
|
|
Print information about the Xen host in I<name : value> format. When
|
|
reporting a Xen bug, please provide this information as part of the
|
|
bug report. See I<http://wiki.xen.org/xenwiki/ReportingBugs> on how to
|
|
report Xen bugs.
|
|
|
|
Sample output looks as follows:
|
|
|
|
host : scarlett
|
|
release : 3.1.0-rc4+
|
|
version : #1001 SMP Wed Oct 19 11:09:54 UTC 2011
|
|
machine : x86_64
|
|
nr_cpus : 4
|
|
nr_nodes : 1
|
|
cores_per_socket : 4
|
|
threads_per_core : 1
|
|
cpu_mhz : 2266
|
|
hw_caps : bfebfbff:28100800:00000000:00003b40:009ce3bd:00000000:00000001:00000000
|
|
virt_caps : hvm hvm_directio
|
|
total_memory : 6141
|
|
free_memory : 4274
|
|
free_cpus : 0
|
|
outstanding_claims : 0
|
|
xen_major : 4
|
|
xen_minor : 2
|
|
xen_extra : -unstable
|
|
xen_caps : xen-3.0-x86_64 xen-3.0-x86_32p hvm-3.0-x86_32 hvm-3.0-x86_32p hvm-3.0-x86_64
|
|
xen_scheduler : credit
|
|
xen_pagesize : 4096
|
|
platform_params : virt_start=0xffff800000000000
|
|
xen_changeset : Wed Nov 02 17:09:09 2011 +0000 24066:54a5e994a241
|
|
xen_commandline : com1=115200,8n1 guest_loglvl=all dom0_mem=750M console=com1
|
|
cc_compiler : gcc version 4.4.5 (Debian 4.4.5-8)
|
|
cc_compile_by : sstabellini
|
|
cc_compile_domain : uk.xensource.com
|
|
cc_compile_date : Tue Nov 8 12:03:05 UTC 2011
|
|
xend_config_format : 4
|
|
|
|
|
|
B<FIELDS>
|
|
|
|
Not all fields will be explained here, but some of the less obvious
|
|
ones deserve explanation:
|
|
|
|
=over 4
|
|
|
|
=item B<hw_caps>
|
|
|
|
A vector showing what hardware capabilities are supported by your
|
|
processor. This is equivalent to, though more cryptic, the flags
|
|
field in /proc/cpuinfo on a normal Linux machine: they both derive from
|
|
the feature bits returned by the cpuid command on x86 platforms.
|
|
|
|
=item B<free_memory>
|
|
|
|
Available memory (in MB) not allocated to Xen, or any other domains, or
|
|
claimed for domains.
|
|
|
|
=item B<outstanding_claims>
|
|
|
|
When a claim call is done (see L<xl.conf>) a reservation for a specific
|
|
amount of pages is set and also a global value is incremented. This
|
|
global value (outstanding_claims) is then reduced as the domain's memory
|
|
is populated and eventually reaches zero. Most of the time the value will
|
|
be zero, but if you are launching multiple guests, and B<claim_mode> is
|
|
enabled, this value can increase/decrease. Note that the value also
|
|
affects the B<free_memory> - as it will reflect the free memory
|
|
in the hypervisor minus the outstanding pages claimed for guests.
|
|
See xl I<info> B<claims> parameter for detailed listing.
|
|
|
|
=item B<xen_caps>
|
|
|
|
The Xen version and architecture. Architecture values can be one of:
|
|
x86_32, x86_32p (i.e. PAE enabled), x86_64, ia64.
|
|
|
|
=item B<xen_changeset>
|
|
|
|
The Xen mercurial changeset id. Very useful for determining exactly
|
|
what version of code your Xen system was built from.
|
|
|
|
=back
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-n>, B<--numa>
|
|
|
|
List host NUMA topology information
|
|
|
|
=back
|
|
|
|
=item B<top>
|
|
|
|
Executes the B<xentop> command, which provides real time monitoring of
|
|
domains. Xentop is a curses interface, and reasonably self
|
|
explanatory.
|
|
|
|
=item B<uptime>
|
|
|
|
Prints the current uptime of the domains running.
|
|
|
|
=item B<claims>
|
|
|
|
Prints information about outstanding claims by the guests. This provides
|
|
the outstanding claims and currently populated memory count for the guests.
|
|
These values added up reflect the global outstanding claim value, which
|
|
is provided via the I<info> argument, B<outstanding_claims> value.
|
|
The B<Mem> column has the cumulative value of outstanding claims and
|
|
the total amount of memory that has been right now allocated to the guest.
|
|
|
|
B<EXAMPLE>
|
|
|
|
An example format for the list is as follows:
|
|
|
|
Name ID Mem VCPUs State Time(s) Claimed
|
|
Domain-0 0 2047 4 r----- 19.7 0
|
|
OL5 2 2048 1 --p--- 0.0 847
|
|
OL6 3 1024 4 r----- 5.9 0
|
|
Windows_XP 4 2047 1 --p--- 0.0 1989
|
|
|
|
In which it can be seen that the OL5 guest still has 847MB of claimed
|
|
memory (out of the total 2048MB where 1191MB has been allocated to
|
|
the guest).
|
|
|
|
=back
|
|
|
|
=head1 SCHEDULER SUBCOMMANDS
|
|
|
|
Xen ships with a number of domain schedulers, which can be set at boot
|
|
time with the B<sched=> parameter on the Xen command line. By
|
|
default B<credit> is used for scheduling.
|
|
|
|
=over 4
|
|
|
|
=item B<sched-credit> [I<OPTIONS>]
|
|
|
|
Set or get credit scheduler parameters. The credit scheduler is a
|
|
proportional fair share CPU scheduler built from the ground up to be
|
|
work conserving on SMP hosts.
|
|
|
|
Each domain (including Domain0) is assigned a weight and a cap.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-d DOMAIN>, B<--domain=DOMAIN>
|
|
|
|
Specify domain for which scheduler parameters are to be modified or retrieved.
|
|
Mandatory for modifying scheduler parameters.
|
|
|
|
=item B<-w WEIGHT>, B<--weight=WEIGHT>
|
|
|
|
A domain with a weight of 512 will get twice as much CPU as a domain
|
|
with a weight of 256 on a contended host. Legal weights range from 1
|
|
to 65535 and the default is 256.
|
|
|
|
=item B<-c CAP>, B<--cap=CAP>
|
|
|
|
The cap optionally fixes the maximum amount of CPU a domain will be
|
|
able to consume, even if the host system has idle CPU cycles. The cap
|
|
is expressed in percentage of one physical CPU: 100 is 1 physical CPU,
|
|
50 is half a CPU, 400 is 4 CPUs, etc. The default, 0, means there is
|
|
no upper cap.
|
|
|
|
NB: Many systems have features that will scale down the computing
|
|
power of a cpu that is not 100% utilized. This can be in the
|
|
operating system, but can also sometimes be below the operating system
|
|
in the BIOS. If you set a cap such that individual cores are running
|
|
at less than 100%, this may have an impact on the performance of your
|
|
workload over and above the impact of the cap. For example, if your
|
|
processor runs at 2GHz, and you cap a vm at 50%, the power management
|
|
system may also reduce the clock speed to 1GHz; the effect will be
|
|
that your VM gets 25% of the available power (50% of 1GHz) rather than
|
|
50% (50% of 2GHz). If you are not getting the performance you expect,
|
|
look at performance and cpufreq options in your operating system and
|
|
your BIOS.
|
|
|
|
=item B<-p CPUPOOL>, B<--cpupool=CPUPOOL>
|
|
|
|
Restrict output to domains in the specified cpupool.
|
|
|
|
=item B<-s>, B<--schedparam>
|
|
|
|
Specify to list or set pool-wide scheduler parameters.
|
|
|
|
=item B<-t TSLICE>, B<--tslice_ms=TSLICE>
|
|
|
|
Timeslice tells the scheduler how long to allow VMs to run before
|
|
pre-empting. The default is 30ms. Valid ranges are 1ms to 1000ms.
|
|
The length of the timeslice (in ms) must be higher than the length of
|
|
the ratelimit (see below).
|
|
|
|
=item B<-r RLIMIT>, B<--ratelimit_us=RLIMIT>
|
|
|
|
Ratelimit attempts to limit the number of schedules per second. It
|
|
sets a minimum amount of time (in microseconds) a VM must run before
|
|
we will allow a higher-priority VM to pre-empt it. The default value
|
|
is 1000 microseconds (1ms). Valid range is 100 to 500000 (500ms).
|
|
The ratelimit length must be lower than the timeslice length.
|
|
|
|
=back
|
|
|
|
B<COMBINATION>
|
|
|
|
The following is the effect of combining the above options:
|
|
|
|
=over 4
|
|
|
|
=item B<E<lt>nothingE<gt>> : List all domain params and sched params from all pools
|
|
|
|
=item B<-d [domid]> : List domain params for domain [domid]
|
|
|
|
=item B<-d [domid] [params]> : Set domain params for domain [domid]
|
|
|
|
=item B<-p [pool]> : list all domains and sched params for [pool]
|
|
|
|
=item B<-s> : List sched params for poolid 0
|
|
|
|
=item B<-s [params]> : Set sched params for poolid 0
|
|
|
|
=item B<-p [pool] -s> : List sched params for [pool]
|
|
|
|
=item B<-p [pool] -s [params]> : Set sched params for [pool]
|
|
|
|
=item B<-p [pool] -d>... : Illegal
|
|
|
|
=back
|
|
|
|
=item B<sched-credit2> [I<OPTIONS>]
|
|
|
|
Set or get credit2 scheduler parameters. The credit2 scheduler is a
|
|
proportional fair share CPU scheduler built from the ground up to be
|
|
work conserving on SMP hosts.
|
|
|
|
Each domain (including Domain0) is assigned a weight.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-d DOMAIN>, B<--domain=DOMAIN>
|
|
|
|
Specify domain for which scheduler parameters are to be modified or retrieved.
|
|
Mandatory for modifying scheduler parameters.
|
|
|
|
=item B<-w WEIGHT>, B<--weight=WEIGHT>
|
|
|
|
A domain with a weight of 512 will get twice as much CPU as a domain
|
|
with a weight of 256 on a contended host. Legal weights range from 1
|
|
to 65535 and the default is 256.
|
|
|
|
=item B<-p CPUPOOL>, B<--cpupool=CPUPOOL>
|
|
|
|
Restrict output to domains in the specified cpupool.
|
|
|
|
=back
|
|
|
|
=item B<sched-sedf> [I<OPTIONS>]
|
|
|
|
Set or get Simple EDF (Earliest Deadline First) scheduler parameters. This
|
|
scheduler provides weighted CPU sharing in an intuitive way and uses
|
|
realtime-algorithms to ensure time guarantees. For more information see
|
|
docs/misc/sedf_scheduler_mini-HOWTO.txt in the Xen distribution.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-d DOMAIN>, B<--domain=DOMAIN>
|
|
|
|
Specify domain for which scheduler parameters are to be modified or retrieved.
|
|
Mandatory for modifying scheduler parameters.
|
|
|
|
=item B<-p PERIOD>, B<--period=PERIOD>
|
|
|
|
The normal EDF scheduling usage in milliseconds.
|
|
|
|
=item B<-s SLICE>, B<--slice=SLICE>
|
|
|
|
The normal EDF scheduling usage in milliseconds.
|
|
|
|
=item B<-l LATENCY>, B<--latency=LATENCY>
|
|
|
|
Scaled period if domain is doing heavy I/O.
|
|
|
|
=item B<-e EXTRA>, B<--extra=EXTRA>
|
|
|
|
Flag for allowing domain to run in extra time (0 or 1).
|
|
|
|
=item B<-w WEIGHT>, B<--weight=WEIGHT>
|
|
|
|
Another way of setting CPU slice.
|
|
|
|
=item B<-c CPUPOOL>, B<--cpupool=CPUPOOL>
|
|
|
|
Restrict output to domains in the specified cpupool.
|
|
|
|
=back
|
|
|
|
=item B<sched-rtds> [I<OPTIONS>]
|
|
|
|
Set or get rtds (Real Time Deferrable Server) scheduler parameters.
|
|
This rt scheduler applies Preemptive Global Earliest Deadline First
|
|
real-time scheduling algorithm to schedule VCPUs in the system.
|
|
Each VCPU has a dedicated period and budget.
|
|
VCPUs in the same domain have the same period and budget.
|
|
While scheduled, a VCPU burns its budget.
|
|
A VCPU has its budget replenished at the beginning of each period;
|
|
Unused budget is discarded at the end of each period.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-d DOMAIN>, B<--domain=DOMAIN>
|
|
|
|
Specify domain for which scheduler parameters are to be modified or retrieved.
|
|
Mandatory for modifying scheduler parameters.
|
|
|
|
=item B<-p PERIOD>, B<--period=PERIOD>
|
|
|
|
Period of time, in microseconds, over which to replenish the budget.
|
|
|
|
=item B<-b BUDGET>, B<--budget=BUDGET>
|
|
|
|
Amount of time, in microseconds, that the VCPU will be allowed
|
|
to run every period.
|
|
|
|
=item B<-c CPUPOOL>, B<--cpupool=CPUPOOL>
|
|
|
|
Restrict output to domains in the specified cpupool.
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=head1 CPUPOOLS COMMANDS
|
|
|
|
Xen can group the physical cpus of a server in cpu-pools. Each physical CPU is
|
|
assigned at most to one cpu-pool. Domains are each restricted to a single
|
|
cpu-pool. Scheduling does not cross cpu-pool boundaries, so each cpu-pool has
|
|
an own scheduler.
|
|
Physical cpus and domains can be moved from one cpu-pool to another only by an
|
|
explicit command.
|
|
Cpu-pools can be specified either by name or by id.
|
|
|
|
=over 4
|
|
|
|
=item B<cpupool-create> [I<OPTIONS>] [I<ConfigFile>] [I<Variable=Value> ...]
|
|
|
|
Create a cpu pool based an config from a I<ConfigFile> or command-line
|
|
parameters. Variable settings from the I<ConfigFile> may be altered
|
|
by specifying new or additional assignments on the command line.
|
|
|
|
See the L<xlcpupool.cfg(5)> manpage for more information.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-f=FILE>, B<--defconfig=FILE>
|
|
|
|
Use the given configuration file.
|
|
|
|
=back
|
|
|
|
=item B<cpupool-list> [I<-c|--cpus>] [I<cpu-pool>]
|
|
|
|
List CPU pools on the host.
|
|
If I<-c> is specified, B<xl> prints a list of CPUs used by I<cpu-pool>.
|
|
|
|
=item B<cpupool-destroy> I<cpu-pool>
|
|
|
|
Deactivates a cpu pool.
|
|
This is possible only if no domain is active in the cpu-pool.
|
|
|
|
=item B<cpupool-rename> I<cpu-pool> <newname>
|
|
|
|
Renames a cpu-pool to I<newname>.
|
|
|
|
=item B<cpupool-cpu-add> I<cpu-pool> I<cpus|node:nodes>
|
|
|
|
Adds one or more CPUs or NUMA nodes to I<cpu-pool>. CPUs and NUMA
|
|
nodes can be specified as single CPU/node IDs or as ranges.
|
|
|
|
For example:
|
|
|
|
(a) xl cpupool-cpu-add mypool 4
|
|
(b) xl cpupool-cpu-add mypool 1,5,10-16,^13
|
|
(c) xl cpupool-cpu-add mypool node:0,nodes:2-3,^10-12,8
|
|
|
|
means adding CPU 4 to mypool, in (a); adding CPUs 1,5,10,11,12,14,15
|
|
and 16, in (b); and adding all the CPUs of NUMA nodes 0, 2 and 3,
|
|
plus CPU 8, but keeping out CPUs 10,11,12, in (c).
|
|
|
|
All the specified CPUs that can be added to the cpupool will be added
|
|
to it. If some CPU can't (e.g., because they're already part of another
|
|
cpupool), an error is reported about each one of them.
|
|
|
|
=item B<cpupool-cpu-remove> I<cpus|node:nodes>
|
|
|
|
Removes one or more CPUs or NUMA nodes from I<cpu-pool>. CPUs and NUMA
|
|
nodes can be specified as single CPU/node IDs or as ranges, using the
|
|
exact same syntax as in B<cpupool-cpu-add> above.
|
|
|
|
=item B<cpupool-migrate> I<domain> I<cpu-pool>
|
|
|
|
Moves a domain specified by domain-id or domain-name into a cpu-pool.
|
|
|
|
=item B<cpupool-numa-split>
|
|
|
|
Splits up the machine into one cpu-pool per numa node.
|
|
|
|
=back
|
|
|
|
=head1 VIRTUAL DEVICE COMMANDS
|
|
|
|
Most virtual devices can be added and removed while guests are
|
|
running, assuming that the necessary support exists in the guest. The
|
|
effect to the guest OS is much the same as any hotplug event.
|
|
|
|
=head2 BLOCK DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<block-attach> I<domain-id> I<disc-spec-component(s)> ...
|
|
|
|
Create a new virtual block device. This will trigger a hotplug event
|
|
for the guest.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<domain-id>
|
|
|
|
The domain id of the guest domain that the device will be attached to.
|
|
|
|
=item I<disc-spec-component>
|
|
|
|
A disc specification in the same format used for the B<disk> variable in
|
|
the domain config file. See
|
|
L<http://xenbits.xen.org/docs/unstable/misc/xl-disk-configuration.txt>.
|
|
|
|
=back
|
|
|
|
=item B<block-detach> I<domain-id> I<devid> [B<--force>]
|
|
|
|
Detach a domain's virtual block device. I<devid> may be the symbolic
|
|
name or the numeric device id given to the device by domain 0. You
|
|
will need to run B<xl block-list> to determine that number.
|
|
|
|
Detaching the device requires the cooperation of the domain. If the
|
|
domain fails to release the device (perhaps because the domain is hung
|
|
or is still using the device), the detach will fail. The B<--force>
|
|
parameter will forcefully detach the device, but may cause IO errors
|
|
in the domain.
|
|
|
|
=item B<block-list> I<domain-id>
|
|
|
|
List virtual block devices for a domain.
|
|
|
|
=item B<cd-insert> I<domain-id> I<VirtualDevice> I<target>
|
|
|
|
Insert a cdrom into a guest domain's existing virtial cd drive. The
|
|
virtual drive must already exist but can be current empty.
|
|
|
|
Only works with HVM domains.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<VirtualDevice>
|
|
|
|
How the device should be presented to the guest domain; for example "hdc".
|
|
|
|
=item I<target>
|
|
|
|
the target path in the backend domain (usually domain 0) to be
|
|
exported; Can be a block device or a file etc. See B<target> in
|
|
F<docs/misc/xl-disk-configuration.txt>.
|
|
|
|
=back
|
|
|
|
=item B<cd-eject> I<domain-id> I<VirtualDevice>
|
|
|
|
Eject a cdrom from a guest's virtual cd drive. Only works with HVM domains.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item I<VirtualDevice>
|
|
|
|
How the device should be presented to the guest domain; for example "hdc".
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=head2 NETWORK DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<network-attach> I<domain-id> I<network-device>
|
|
|
|
Creates a new network device in the domain specified by I<domain-id>.
|
|
I<network-device> describes the device to attach, using the same format as the
|
|
B<vif> string in the domain config file. See L<xl.cfg> and
|
|
L<http://xenbits.xen.org/docs/unstable/misc/xl-network-configuration.html>
|
|
for more informations.
|
|
|
|
=item B<network-detach> I<domain-id> I<devid|mac>
|
|
|
|
Removes the network device from the domain specified by I<domain-id>.
|
|
I<devid> is the virtual interface device number within the domain
|
|
(i.e. the 3 in vif22.3). Alternatively the I<mac> address can be used to
|
|
select the virtual interface to detach.
|
|
|
|
=item B<network-list> I<domain-id>
|
|
|
|
List virtual network interfaces for a domain.
|
|
|
|
=back
|
|
|
|
=head2 CHANNEL DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<channel-list> I<domain-id>
|
|
|
|
List virtual channel interfaces for a domain.
|
|
|
|
=back
|
|
|
|
=head2 VTPM DEVICES
|
|
|
|
=over 4
|
|
|
|
=item B<vtpm-attach> I<domain-id> I<vtpm-device>
|
|
|
|
Creates a new vtpm device in the domain specified by I<domain-id>.
|
|
I<vtpm-device> describes the device to attach, using the same format as the
|
|
B<vtpm> string in the domain config file. See L<xl.cfg> for
|
|
more information.
|
|
|
|
=item B<vtpm-detach> I<domain-id> I<devid|uuid>
|
|
|
|
Removes the vtpm device from the domain specified by I<domain-id>.
|
|
I<devid> is the numeric device id given to the virtual trusted
|
|
platform module device. You will need to run B<xl vtpm-list> to determine that number.
|
|
Alternatively the I<uuid> of the vtpm can be used to
|
|
select the virtual device to detach.
|
|
|
|
=item B<vtpm-list> I<domain-id>
|
|
|
|
List virtual trusted platform modules for a domain.
|
|
|
|
=back
|
|
|
|
=head1 PCI PASS-THROUGH
|
|
|
|
=over 4
|
|
|
|
=item B<pci-assignable-list>
|
|
|
|
List all the assignable PCI devices.
|
|
These are devices in the system which are configured to be
|
|
available for passthrough and are bound to a suitable PCI
|
|
backend driver in domain 0 rather than a real driver.
|
|
|
|
=item B<pci-assignable-add> I<BDF>
|
|
|
|
Make the device at PCI Bus/Device/Function BDF assignable to guests.
|
|
This will bind the device to the pciback driver. If it is already
|
|
bound to a driver, it will first be unbound, and the original driver
|
|
stored so that it can be re-bound to the same driver later if desired.
|
|
If the device is already bound, it will return success.
|
|
|
|
CAUTION: This will make the device unusable by Domain 0 until it is
|
|
returned with pci-assignable-remove. Care should therefore be taken
|
|
not to do this on a device critical to domain 0's operation, such as
|
|
storage controllers, network interfaces, or GPUs that are currently
|
|
being used.
|
|
|
|
=item B<pci-assignable-remove> [I<-r>] I<BDF>
|
|
|
|
Make the device at PCI Bus/Device/Function BDF assignable to guests. This
|
|
will at least unbind the device from pciback. If the -r option is specified,
|
|
it will also attempt to re-bind the device to its original driver, making it
|
|
usable by Domain 0 again. If the device is not bound to pciback, it will
|
|
return success.
|
|
|
|
=item B<pci-attach> I<domain-id> I<BDF>
|
|
|
|
Hot-plug a new pass-through pci device to the specified domain.
|
|
B<BDF> is the PCI Bus/Device/Function of the physical device to pass-through.
|
|
|
|
=item B<pci-detach> [I<-f>] I<domain-id> I<BDF>
|
|
|
|
Hot-unplug a previously assigned pci device from a domain. B<BDF> is the PCI
|
|
Bus/Device/Function of the physical device to be removed from the guest domain.
|
|
|
|
If B<-f> is specified, B<xl> is going to forcefully remove the device even
|
|
without guest's collaboration.
|
|
|
|
=item B<pci-list> I<domain-id>
|
|
|
|
List pass-through pci devices for a domain.
|
|
|
|
=back
|
|
|
|
=head1 TMEM
|
|
|
|
=over 4
|
|
|
|
=item B<tmem-list> I[<-l>] I<domain-id>
|
|
|
|
List tmem pools. If I<-l> is specified, also list tmem stats.
|
|
|
|
=item B<tmem-freeze> I<domain-id>
|
|
|
|
Freeze tmem pools.
|
|
|
|
=item B<tmem-thaw> I<domain-id>
|
|
|
|
Thaw tmem pools.
|
|
|
|
=item B<tmem-set> I<domain-id> [I<OPTIONS>]
|
|
|
|
Change tmem settings.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-w> I<WEIGHT>
|
|
|
|
Weight (int)
|
|
|
|
=item B<-c> I<CAP>
|
|
|
|
Cap (int)
|
|
|
|
=item B<-p> I<COMPRESS>
|
|
|
|
Compress (int)
|
|
|
|
=back
|
|
|
|
=item B<tmem-shared-auth> I<domain-id> [I<OPTIONS>]
|
|
|
|
De/authenticate shared tmem pool.
|
|
|
|
B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-u> I<UUID>
|
|
|
|
Specify uuid (abcdef01-2345-6789-1234-567890abcdef)
|
|
|
|
=item B<-a> I<AUTH>
|
|
|
|
0=auth,1=deauth
|
|
|
|
=back
|
|
|
|
=item B<tmem-freeable>
|
|
|
|
Get information about how much freeable memory (MB) is in-use by tmem.
|
|
|
|
=back
|
|
|
|
=head1 FLASK
|
|
|
|
B<FLASK> is a security framework that defines a mandatory access control policy
|
|
providing fine-grained controls over Xen domains, allowing the policy writer
|
|
to define what interactions between domains, devices, and the hypervisor are
|
|
permitted. Some example of what you can do using XSM/FLASK:
|
|
- Prevent two domains from communicating via event channels or grants
|
|
- Control which domains can use device passthrough (and which devices)
|
|
- Restrict or audit operations performed by privileged domains
|
|
- Prevent a privileged domain from arbitrarily mapping pages from other
|
|
domains.
|
|
|
|
You can find more details on how to use FLASK and an example security
|
|
policy here: L<http://xenbits.xen.org/docs/unstable/misc/xsm-flask.txt>
|
|
|
|
=over 4
|
|
|
|
=item B<getenforce>
|
|
|
|
Determine if the FLASK security module is loaded and enforcing its policy.
|
|
|
|
=item B<setenforce> I<1|0|Enforcing|Permissive>
|
|
|
|
Enable or disable enforcing of the FLASK access controls. The default is
|
|
permissive, but this can be changed to enforcing by specifying "flask=enforcing"
|
|
or "flask=late" on the hypervisor's command line.
|
|
|
|
=item B<loadpolicy> I<policy-file>
|
|
|
|
Load FLASK policy from the given policy file. The initial policy is provided to
|
|
the hypervisor as a multiboot module; this command allows runtime updates to the
|
|
policy. Loading new security policy will reset runtime changes to device labels.
|
|
|
|
=back
|
|
|
|
=head1 CACHE MONITORING TECHNOLOGY
|
|
|
|
Intel Haswell and later server platforms offer monitoring capability in each
|
|
logical processor to measure specific platform shared resource metric, for
|
|
example, L3 cache occupancy. In Xen implementation, the monitoring granularity
|
|
is domain level. To monitor a specific domain, just attach the domain id with
|
|
the monitoring service. When the domain doesn't need to be monitored any more,
|
|
detach the domain id from the monitoring service.
|
|
|
|
Intel Broadwell and later server platforms also offer total/local memory
|
|
bandwidth monitoring. Xen supports per-domain monitoring for these two
|
|
additional monitoring types. Both memory bandwidth monitoring and L3 cache
|
|
occupancy monitoring share the same set of underlying monitoring service. Once
|
|
a domain is attached to the monitoring service, monitoring data can be showed
|
|
for any of these monitoring types.
|
|
|
|
=over 4
|
|
|
|
=item B<psr-cmt-attach> [I<domain-id>]
|
|
|
|
attach: Attach the platform shared resource monitoring service to a domain.
|
|
|
|
=item B<psr-cmt-detach> [I<domain-id>]
|
|
|
|
detach: Detach the platform shared resource monitoring service from a domain.
|
|
|
|
=item B<psr-cmt-show> [I<psr-monitor-type>] [I<domain-id>]
|
|
|
|
Show monitoring data for a certain domain or all domains. Current supported
|
|
monitor types are:
|
|
- "cache-occupancy": showing the L3 cache occupancy(KB).
|
|
- "total-mem-bandwidth": showing the total memory bandwidth(KB/s).
|
|
- "local-mem-bandwidth": showing the local memory bandwidth(KB/s).
|
|
|
|
=back
|
|
|
|
=head1 TO BE DOCUMENTED
|
|
|
|
We need better documentation for:
|
|
|
|
=over 4
|
|
|
|
=item B<tmem>
|
|
|
|
Transcendent Memory.
|
|
|
|
=back
|
|
|
|
=head1 SEE ALSO
|
|
|
|
The following man pages:
|
|
|
|
L<xl.cfg>(5), L<xlcpupool.cfg>(5), B<xentop>(1)
|
|
|
|
And the following documents on the xen.org website:
|
|
|
|
L<http://xenbits.xen.org/docs/unstable/misc/xl-network-configuration.html>
|
|
L<http://xenbits.xen.org/docs/unstable/misc/xl-disk-configuration.txt>
|
|
L<http://xenbits.xen.org/docs/unstable/misc/xsm-flask.txt>
|
|
|
|
For systems that don't automatically bring CPU online:
|
|
|
|
L<http://wiki.xen.org/wiki/Paravirt_Linux_CPU_Hotplug>
|
|
|
|
=head1 BUGS
|
|
|
|
Send bugs to xen-devel@lists.xen.org, see
|
|
http://wiki.xen.org/xenwiki/ReportingBugs on how to send bug reports.
|