docs: create Memory Bandwidth Allocation (MBA) feature document
This patch creates MBA feature document in doc/features/. It describes key points to implement MBA which is described in details in Intel SDM "Introduction to Memory Bandwidth Allocation". Signed-off-by: Yi Sun <yi.y.sun@linux.intel.com> Reviewed-by: Roger Pau Monné <roger.pau@citrix.com>
This commit is contained in:
1 parent
896ee3980e
commit
0062b96961
1 file changed
+297
@@ -0,0 +1,297 @@
|
||||
% Intel Memory Bandwidth Allocation (MBA) Feature
|
||||
% Revision 1.8
|
||||
|
||||
\clearpage
|
||||
|
||||
# Basics
|
||||
|
||||
---------------- ----------------------------------------------------
|
||||
Status: **Tech Preview**
|
||||
|
||||
Architecture(s): Intel x86
|
||||
|
||||
Component(s): Hypervisor, toolstack
|
||||
|
||||
Hardware: MBA is supported on Skylake Server and beyond
|
||||
---------------- ----------------------------------------------------
|
||||
|
||||
# Terminology
|
||||
|
||||
* CAT Cache Allocation Technology
|
||||
* CBM Capacity BitMasks
|
||||
* CDP Code and Data Prioritization
|
||||
* COS/CLOS Class of Service
|
||||
* HW Hardware
|
||||
* MBA Memory Bandwidth Allocation
|
||||
* MSRs Machine Specific Registers
|
||||
* PSR Intel Platform Shared Resource
|
||||
* THRTL Throttle value or delay value
|
||||
|
||||
# Overview
|
||||
|
||||
The Memory Bandwidth Allocation (MBA) feature provides indirect and approximate
|
||||
control over memory bandwidth available per-core. This feature provides OS/
|
||||
hypervisor the ability to slow misbehaving apps/domains by using a credit-based
|
||||
throttling mechanism.
|
||||
|
||||
# User details
|
||||
|
||||
* Feature Enabling:
|
||||
|
||||
Add "psr=mba" to boot line parameter to enable MBA feature.
|
||||
|
||||
* xl interfaces:
|
||||
|
||||
1. `psr-mba-show [domain-id|domain-name]`:
|
||||
|
||||
Show memory bandwidth throttling for domain. Under different modes, it
|
||||
shows different type of data.
|
||||
|
||||
There are two modes:
|
||||
Linear mode: the input precision is defined as 100-(MBA_MAX). For instance,
|
||||
if the MBA_MAX value is 90, the input precision is 10%. Values not an even
|
||||
multiple of the precision (e.g., 12%) will be rounded down (e.g., to 10%
|
||||
delay applied) by HW automatically. The response of throttling value is
|
||||
linear.
|
||||
|
||||
Non-linear mode: input delay values are powers-of-two from zero to the
|
||||
MBA_MAX value from CPUID. In this case any values not a power of two will
|
||||
be rounded down the next nearest power of two by HW automatically. The
|
||||
response of throttling value is non-linear.
|
||||
|
||||
For linear mode, it shows the decimal value. For non-linear mode, it shows
|
||||
hexadecimal value.
|
||||
|
||||
2. `psr-mba-set [OPTIONS] <domain-id|domain-name> <throttling>`:
|
||||
|
||||
Set memory bandwidth throttling for domain.
|
||||
|
||||
Options:
|
||||
'-s': Specify the socket to process, otherwise all sockets are processed.
|
||||
|
||||
Throttling value set in register implies the approximate amount of delaying
|
||||
the traffic between core and memory. Higher throttling value result in
|
||||
lower bandwidth. The max throttling value (MBA_MAX) supported can be
|
||||
obtained through CPUID inside hypervisor. Users can fetch the MBA_MAX value
|
||||
using the `psr-hwinfo` xl command.
|
||||
|
||||
# Technical details
|
||||
|
||||
MBA is a member of Intel PSR features, it shares the base PSR infrastructure
|
||||
in Xen.
|
||||
|
||||
## Hardware perspective
|
||||
|
||||
MBA defines a range of MSRs to support specifying a delay value (Thrtl) per
|
||||
COS, with details below.
|
||||
|
||||
```
|
||||
+----------------------------+----------------+
|
||||
| MSR (per socket) | Address |
|
||||
+----------------------------+----------------+
|
||||
| IA32_L2_QOS_Ext_BW_Thrtl_0 | 0xD50 |
|
||||
+----------------------------+----------------+
|
||||
| ... | ... |
|
||||
+----------------------------+----------------+
|
||||
| IA32_L2_QOS_Ext_BW_Thrtl_n | 0xD50+n |
|
||||
+----------------------------+----------------+
|
||||
```
|
||||
|
||||
When context switch happens, the COS ID of domain is written to per-hyper-
|
||||
thread MSR `IA32_PQR_ASSOC`, and then hardware enforces bandwidth allocation
|
||||
according to the throttling value stored in the Thrtl MSR register.
|
||||
|
||||
## The relationship between MBA and CAT/CDP
|
||||
|
||||
Generally speaking, MBA is completely independent of CAT/CDP, and any
|
||||
combination may be applied at any time, e.g. enabling MBA with CAT
|
||||
disabled.
|
||||
|
||||
But it needs to be noticed that MBA shares COS infrastructure with CAT,
|
||||
although MBA is enumerated by different CPUID leaf from CAT (which
|
||||
indicates that the max COS of MBA may be different from CAT). In some
|
||||
cases, a domain is permitted to have a COS that is beyond one (or more)
|
||||
of PSR features but within the others. For instance, let's assume the max
|
||||
COS of MBA is 8 but the max COS of L3 CAT is 16, when a domain is assigned
|
||||
9 as COS, the L3 CAT CBM associated to COS 9 would be enforced, but for MBA,
|
||||
the HW works as default value is set since COS 9 is beyond the max COS (8)
|
||||
of MBA.
|
||||
|
||||
## Design Overview
|
||||
|
||||
* Core COS/Thrtl association
|
||||
|
||||
When enforcing Memory Bandwidth Allocation, all cores of domains have
|
||||
the same default Thrtl MSR (COS0) which stores the same Thrtl (0). The
|
||||
default Thrtl MSR is used only in hypervisor and is transparent to tool stack
|
||||
and user.
|
||||
|
||||
System administrators can change PSR allocation policy at runtime by
|
||||
using the tool stack. Since MBA shares COS ID with CAT/CDP, a COS ID
|
||||
corresponds to a 2-tuple, like [CBM, Thrtl] with only-CAT enabled, when CDP
|
||||
is enabled, the COS ID corresponds to a 3-tuple, like [Code_CBM, Data_CBM,
|
||||
Thrtl]. If neither CAT nor CDP is enabled, things are easier, since one COS
|
||||
ID corresponds to one Thrtl.
|
||||
|
||||
* VCPU schedule
|
||||
|
||||
This part reuses CAT COS infrastructure.
|
||||
|
||||
* Multi-sockets
|
||||
|
||||
Different sockets may have different MBA capabilities (like max COS)
|
||||
although it is consistent on the same socket. So the capability
|
||||
of per-socket MBA is specified.
|
||||
|
||||
This part reuses CAT COS infrastructure.
|
||||
|
||||
## Implementation Description
|
||||
|
||||
* Hypervisor interfaces:
|
||||
|
||||
1. Boot line param: "psr=mba" to enable the feature.
|
||||
|
||||
2. SYSCTL:
|
||||
- XEN_SYSCTL_PSR_MBA_get_info: Get system MBA information.
|
||||
|
||||
3. DOMCTL:
|
||||
- XEN_DOMCTL_PSR_MBA_OP_GET_THRTL: Get throttling for a domain.
|
||||
- XEN_DOMCTL_PSR_MBA_OP_SET_THRTL: Set throttling for a domain.
|
||||
|
||||
* xl interfaces:
|
||||
|
||||
1. psr-mba-show [domain-id]
|
||||
Show system/domain runtime MBA throttling value. For linear mode,
|
||||
it shows the decimal value. For non-linear mode, it shows hexadecimal
|
||||
value.
|
||||
=> XEN_SYSCTL_PSR_MBA_get_info/XEN_DOMCTL_PSR_MBA_OP_GET_THRTL
|
||||
|
||||
2. psr-mba-set [OPTIONS] <domain-id> <throttling>
|
||||
Set bandwidth throttling for a domain.
|
||||
=> XEN_DOMCTL_PSR_MBA_OP_SET_THRTL
|
||||
|
||||
3. psr-hwinfo
|
||||
Show PSR HW information, including L3 CAT/CDP/L2 CAT/MBA.
|
||||
=> XEN_SYSCTL_PSR_MBA_get_info
|
||||
|
||||
* Key data structure:
|
||||
|
||||
1. Feature HW info
|
||||
|
||||
```
|
||||
struct {
|
||||
unsigned int thrtl_max;
|
||||
bool linear;
|
||||
} mba;
|
||||
|
||||
- Member `thrtl_max`
|
||||
|
||||
`thrtl_max` is the max throttling value to be set, i.e. MBA_MAX.
|
||||
|
||||
- Member `linear`
|
||||
|
||||
`linear` means the response of delay value is linear or not.
|
||||
|
||||
As mentioned above, MBA is a member of Intel PSR features, it shares the
|
||||
base PSR infrastructure in Xen. For example, the 'cos_max' is a common HW
|
||||
property for all features. So, for other data structure details, please
|
||||
refer to 'intel_psr_cat_cdp.pandoc'.
|
||||
|
||||
# Limitations
|
||||
|
||||
MBA can only work on HW which supports it (check CPUID).
|
||||
|
||||
# Testing
|
||||
|
||||
We can execute these commands to verify MBA on different HWs supporting them.
|
||||
|
||||
For example:
|
||||
1. User can get the MBA hardware info through 'psr-hwinfo' command. From
|
||||
result, user can know if this hardware works under linear mode or non-
|
||||
linear mode, the max throttling value (MBA_MAX) and so on.
|
||||
|
||||
root@:~$ xl psr-hwinfo --mba
|
||||
Memory Bandwidth Allocation (MBA):
|
||||
Socket ID : 0
|
||||
Linear Mode : Enabled
|
||||
Maximum COS : 7
|
||||
Maximum Throttling Value: 90
|
||||
Default Throttling Value: 0
|
||||
|
||||
2. Then, user can set a throttling value to a domain. For example, set '10',
|
||||
i.e 10% delay.
|
||||
|
||||
root@:~$ xl psr-mba-set 1 10
|
||||
|
||||
3. User can check the current configuration of the domain through
|
||||
'psr-mab-show'. For linear mode, the decimal value is shown.
|
||||
|
||||
root@:~$ xl psr-mba-show 1
|
||||
Socket ID : 0
|
||||
Default THRTL : 0
|
||||
ID NAME THRTL
|
||||
1 ubuntu14 10
|
||||
|
||||
# Areas for improvement
|
||||
|
||||
N/A
|
||||
|
||||
# Known issues
|
||||
|
||||
N/A
|
||||
|
||||
# References
|
||||
|
||||
"INTEL RESOURCE DIRECTOR TECHNOLOGY (INTEL RDT) ALLOCATION FEATURES" [Intel 64 and IA-32 Architectures Software Developer Manuals, vol3](http://www.intel.com/content/www/us/en/processors/architectures-software-developer-manuals.html)
|
||||
|
||||
# History
|
||||
|
||||
------------------------------------------------------------------------
|
||||
Date Revision Version Notes
|
||||
---------- -------- -------- -------------------------------------------
|
||||
2017-01-10 1.0 Xen 4.9 Design document written
|
||||
2017-07-10 1.1 Xen 4.10 Changes:
|
||||
1. Modify data structure according to latest
|
||||
codes;
|
||||
2. Add content for 'Areas for improvement';
|
||||
3. Other minor changes.
|
||||
2017-08-09 1.2 Xen 4.10 Changes:
|
||||
1. Remove a special character to avoid error when
|
||||
building pandoc.
|
||||
2017-08-15 1.3 Xen 4.10 Changes:
|
||||
1. Add terminology 'HW'.
|
||||
2. Change 'COS ID of VCPU' to 'COS ID of domain'.
|
||||
3. Change 'COS register' to 'Thrtl MSR'.
|
||||
4. Explain the value shown for 'psr-mba-show' under
|
||||
different modes.
|
||||
5. Remove content in 'Areas for improvement'.
|
||||
2017-08-16 1.4 Xen 4.10 Changes:
|
||||
1. Add '<>' for mandatory argument.
|
||||
2017-08-30 1.5 Xen 4.10 Changes:
|
||||
1. Modify words in 'Overview' to make it easier to
|
||||
understand.
|
||||
2. Explain 'linear/non-linear' modes before mention
|
||||
them.
|
||||
3. Explain throttling value more accurate.
|
||||
4. Explain 'MBA_MAX'.
|
||||
5. Correct some words in 'Design Overview'.
|
||||
6. Change 'mba_info' to 'mba' according to code
|
||||
changes. Also, modify contents of it.
|
||||
7. Add context in 'Testing' part to make things
|
||||
more clear.
|
||||
8. Remove 'n<64' to avoid out-of-sync.
|
||||
2017-09-21 1.6 Xen 4.10 Changes:
|
||||
1. Add 'domain-name' as parameter of 'psr-mba-show/
|
||||
psr-mba-set'.
|
||||
2. Fix some wordings.
|
||||
3. Explain how user can know the MBA_MAX.
|
||||
4. Move the description of 'Linear mode/Non-linear
|
||||
mode' into section of 'psr-mba-show'.
|
||||
5. Change 'per-thread' to 'per-hyper-thread'.
|
||||
2017-09-29 1.7 Xen 4.10 Changes:
|
||||
1. Correct some words.
|
||||
2. Change 'xl psr-mba-set 1 0xa' to
|
||||
'xl psr-mba-set 1 10'
|
||||
2017-10-08 1.8 Xen 4.10 Changes:
|
||||
1. Correct some words.
|
||||
---------- -------- -------- -------------------------------------------
|
||||