x86/hpet: Factor hpet_enable_legacy_replacement_mode() out of hpet_setup()
... in preparation to introduce a second caller. No functional change. Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com> Reviewed-by: Jan Beulich <jbeulich@suse.com> Tested-by: Frédéric Pierret <frederic.pierret@qubes-os.org>
This commit is contained in:
1 parent
2b05d427a0
commit
238168b5bc
2 files changed
+68
-54
No files matched your search
+62
-54
@@ -754,11 +754,70 @@ int hpet_legacy_irq_tick(void)
|
||||
}
|
||||
|
||||
static u32 *hpet_boot_cfg;
|
||||
static uint64_t __initdata hpet_rate;
|
||||
|
||||
bool __init hpet_enable_legacy_replacement_mode(void)
|
||||
{
|
||||
unsigned int cfg, c0_cfg, ticks, count;
|
||||
|
||||
if ( !hpet_rate ||
|
||||
!(hpet_read32(HPET_ID) & HPET_ID_LEGSUP) ||
|
||||
((cfg = hpet_read32(HPET_CFG)) & HPET_CFG_LEGACY) )
|
||||
return false;
|
||||
|
||||
/* Stop the main counter. */
|
||||
hpet_write32(cfg & ~HPET_CFG_ENABLE, HPET_CFG);
|
||||
|
||||
/* Reconfigure channel 0 to be 32bit periodic. */
|
||||
c0_cfg = hpet_read32(HPET_Tn_CFG(0));
|
||||
c0_cfg |= (HPET_TN_ENABLE | HPET_TN_PERIODIC | HPET_TN_SETVAL |
|
||||
HPET_TN_32BIT);
|
||||
hpet_write32(c0_cfg, HPET_Tn_CFG(0));
|
||||
|
||||
/*
|
||||
* The exact period doesn't have to match a legacy PIT. All we need
|
||||
* is an interrupt queued up via the IO-APIC to check routing.
|
||||
*
|
||||
* Use HZ as the frequency.
|
||||
*/
|
||||
ticks = ((SECONDS(1) / HZ) * div_sc(hpet_rate, SECONDS(1), 32)) >> 32;
|
||||
|
||||
count = hpet_read32(HPET_COUNTER);
|
||||
|
||||
/*
|
||||
* HPET_TN_SETVAL above is atrociously documented in the spec.
|
||||
*
|
||||
* Periodic HPET channels have a main comparator register, and
|
||||
* separate "accumulator" register. Despite being named accumulator
|
||||
* in the spec, this is not an accurate description of its behaviour
|
||||
* or purpose.
|
||||
*
|
||||
* Each time an interrupt is generated, the "accumulator" register is
|
||||
* re-added to the comparator set up the new period.
|
||||
*
|
||||
* Normally, writes to the CMP register update both registers.
|
||||
* However, under these semantics, it is impossible to set up a
|
||||
* periodic timer correctly without the main HPET counter being at 0.
|
||||
*
|
||||
* Instead, HPET_TN_SETVAL is a self-clearing control bit which we can
|
||||
* use for periodic timers to mean that the second write to CMP
|
||||
* updates the accumulator only, and not the absolute comparator
|
||||
* value.
|
||||
*
|
||||
* This lets us set a period when the main counter isn't at 0.
|
||||
*/
|
||||
hpet_write32(count + ticks, HPET_Tn_CMP(0));
|
||||
hpet_write32(ticks, HPET_Tn_CMP(0));
|
||||
|
||||
/* Restart the main counter, and legacy mode. */
|
||||
hpet_write32(cfg | HPET_CFG_ENABLE | HPET_CFG_LEGACY, HPET_CFG);
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
u64 __init hpet_setup(void)
|
||||
{
|
||||
static u64 __initdata hpet_rate;
|
||||
unsigned int hpet_id, hpet_period, hpet_cfg;
|
||||
unsigned int hpet_id, hpet_period;
|
||||
unsigned int last, rem;
|
||||
|
||||
if ( hpet_rate )
|
||||
@@ -805,58 +864,7 @@ u64 __init hpet_setup(void)
|
||||
* Reconfigure the HPET into legacy mode to re-establish the timer
|
||||
* interrupt.
|
||||
*/
|
||||
if ( hpet_id & HPET_ID_LEGSUP &&
|
||||
!((hpet_cfg = hpet_read32(HPET_CFG)) & HPET_CFG_LEGACY) )
|
||||
{
|
||||
unsigned int c0_cfg, ticks, count;
|
||||
|
||||
/* Stop the main counter. */
|
||||
hpet_write32(hpet_cfg & ~HPET_CFG_ENABLE, HPET_CFG);
|
||||
|
||||
/* Reconfigure channel 0 to be 32bit periodic. */
|
||||
c0_cfg = hpet_read32(HPET_Tn_CFG(0));
|
||||
c0_cfg |= (HPET_TN_ENABLE | HPET_TN_PERIODIC | HPET_TN_SETVAL |
|
||||
HPET_TN_32BIT);
|
||||
hpet_write32(c0_cfg, HPET_Tn_CFG(0));
|
||||
|
||||
/*
|
||||
* The exact period doesn't have to match a legacy PIT. All we need
|
||||
* is an interrupt queued up via the IO-APIC to check routing.
|
||||
*
|
||||
* Use HZ as the frequency.
|
||||
*/
|
||||
ticks = ((SECONDS(1) / HZ) * div_sc(hpet_rate, SECONDS(1), 32)) >> 32;
|
||||
|
||||
count = hpet_read32(HPET_COUNTER);
|
||||
|
||||
/*
|
||||
* HPET_TN_SETVAL above is atrociously documented in the spec.
|
||||
*
|
||||
* Periodic HPET channels have a main comparator register, and
|
||||
* separate "accumulator" register. Despite being named accumulator
|
||||
* in the spec, this is not an accurate description of its behaviour
|
||||
* or purpose.
|
||||
*
|
||||
* Each time an interrupt is generated, the "accumulator" register is
|
||||
* re-added to the comparator set up the new period.
|
||||
*
|
||||
* Normally, writes to the CMP register update both registers.
|
||||
* However, under these semantics, it is impossible to set up a
|
||||
* periodic timer correctly without the main HPET counter being at 0.
|
||||
*
|
||||
* Instead, HPET_TN_SETVAL is a self-clearing control bit which we can
|
||||
* use for periodic timers to mean that the second write to CMP
|
||||
* updates the accumulator only, and not the absolute comparator
|
||||
* value.
|
||||
*
|
||||
* This lets us set a period when the main counter isn't at 0.
|
||||
*/
|
||||
hpet_write32(count + ticks, HPET_Tn_CMP(0));
|
||||
hpet_write32(ticks, HPET_Tn_CMP(0));
|
||||
|
||||
/* Restart the main counter, and legacy mode. */
|
||||
hpet_write32(hpet_cfg | HPET_CFG_ENABLE | HPET_CFG_LEGACY, HPET_CFG);
|
||||
}
|
||||
hpet_enable_legacy_replacement_mode();
|
||||
|
||||
return hpet_rate;
|
||||
}
|
||||
|
||||
@@ -72,6 +72,12 @@ void hpet_disable(void);
|
||||
*/
|
||||
int hpet_legacy_irq_tick(void);
|
||||
|
||||
/*
|
||||
* Try to enable HPET Legacy Replacement mode. Returns a boolean indicating
|
||||
* whether the HPET configuration was changed.
|
||||
*/
|
||||
bool hpet_enable_legacy_replacement_mode(void);
|
||||
|
||||
/*
|
||||
* Temporarily use an HPET event counter for timer interrupt handling,
|
||||
* rather than using the LAPIC timer. Used for Cx state entry.
|
||||
|
||||