rombios/ata: wait for BSY to clear after write

After rombios transfers the data for a write, it checks the status and
fails if BSY is set. qemu-trad doesn't set BSY for PIO writes, but QEMU
upstream does, and this causes rombios to fail writes because they are
marked as BSY. Instead, wait for BSY to clear after a write.

INT 13 writes are probably rarely used these days, but they are used by
GRUB 2 to write to its environment file which happens by default on
Ubuntu.

Signed-off-by: Ross Lagerwall <ross.lagerwall@citrix.com>
Acked-by: Andrew Cooper <andrew.cooper3@citrix.com>
This commit is contained in:
Ross Lagerwall authored and Jan Beulich committed 2017-06-20 17:13:02 +02:00
1 parent 592e834522
commit 4c09689153
1 file changed
+1 -1
+1 -1
View File
@@ -3226,7 +3226,7 @@ ASM_END
current++;
write_word(ebda_seg, &EbdaData->ata.trsfsectors,current);
count--;
status = inb(iobase1 + ATA_CB_STAT);
status = await_ide(NOT_BSY, iobase1, IDE_TIMEOUT);
if (count == 0) {
if ( (status & (ATA_CB_STAT_BSY | ATA_CB_STAT_RDY | ATA_CB_STAT_DF | ATA_CB_STAT_DRQ | ATA_CB_STAT_ERR) )
!= ATA_CB_STAT_RDY ) {