mirror of
https://github.com/xen-project/xen.git
synced 2026-10-28 02:01:24 +01:00
VT-d: don't needlessly look up DID
If get_iommu_domid() in domain_context_unmap_one() fails, we better
wouldn't clear the context entry in the first place, as we're then unable
to issue the corresponding flush. However, we have no need to look up the
DID in the first place: What needs flushing is very specifically the DID
that was in the context entry before our clearing of it.
Signed-off-by: Jan Beulich <jbeulich@suse.com>
Reviewed-by: Roger Pau Monné <roger.pau@citrix.com>
master commit: 445ab9852d
master date: 2022-04-07 12:29:03 +0200
This commit is contained in:
1 parent
169a2834ef
commit
a6902a6516
1 file changed
+2
-8
@@ -1821,18 +1821,12 @@ int domain_context_unmap_one(
|
||||
return 0;
|
||||
}
|
||||
|
||||
iommu_domid = context_domain_id(*context);
|
||||
|
||||
context_clear_present(*context);
|
||||
context_clear_entry(*context);
|
||||
iommu_sync_cache(context, sizeof(struct context_entry));
|
||||
|
||||
iommu_domid = get_iommu_did(domid, iommu, !domain->is_dying);
|
||||
if ( iommu_domid == -1 )
|
||||
{
|
||||
spin_unlock(&iommu->lock);
|
||||
unmap_vtd_domain_page(context_entries);
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
rc = iommu_flush_context_device(iommu, iommu_domid,
|
||||
PCI_BDF2(bus, devfn),
|
||||
DMA_CCMD_MASK_NOBIT, 0);
|
||||
|
||||